MétaCan
Menu
Back to cohort

Calcification Properties of Saline-Filled Breast Implants

2001· article· en· W2092010115 on OpenAlexaff
Walter Peters, Dennis Smith, Stanley Lugowski, K. P. H. Pritzker, Douglas Holmyard

Bibliographic record

VenuePlastic & Reconstructive Surgery · 2001
Typearticle
Languageen
FieldEngineering
TopicBone Tissue Engineering Materials
Canadian institutionsMount Sinai HospitalWellesley InstituteUniversity of Toronto
Fundersnot available
KeywordsCalcificationImplantMedicineDystrophic calcificationSalineDentistryPathologySurgeryInternal medicine

Abstract

fetched live from OpenAlex

Three patients requested explantation of their saline-filled breast implants. Bilateral calcification had occurred in all six implants. Four of the implants were manufactured by McGhan Corporation (Santa Barbara, Calif.), and two, by the Simaplast Company (Toulon, France). All implants had been inserted in the subglandular plane and had been in place for 7 to 23 years. At the time of explantation, patients were 32, 34, and 44 years old. Calcification on the surface of the implants and capsules was analyzed. Implant surface calcification was clinically evident on all six implants, appearing as ivory-colored, tenaciously adherent deposits, only on the anterior surface of the implant. Capsular calcification, which was observed only microscopically, was characterized by poorly organized, irregularly shaped, calcified agglomerates; this calcification also occurred only on the anterior surface of the capsule, adjacent to the area of calcification on the implant. Ultrastructural analysis of scrapings from the implant surface showed large, electron-dense aggregates of crystals, with individual crystals measuring approximately 40 x 10 x 10 nm. In contrast, capsular calcification was characterized by two patterns of deposition, spherulitic aggregates of needle-shaped crystals and areas of metaplastic bone. The individual crystals were approximately 40 x 10 x 10 nm. Energy-dispersive x-ray spectroscopy of specimens from the areas of calcification on the implant and capsule surfaces demonstrated calcium and phosphorus. Electron diffraction of crystals from the implant and capsule surfaces demonstrated the D-spacings characteristic of calcium apatite. There were many differences between the calcification properties of these six saline implants and those of silicone gel implants. For example, mineralization has not been observed on the surface of gel implants, but in these saline implants it occurred primarily on the implant surface. Also, capsular calcification has been observed clinically in gel implants across the surface of the capsule (except at the site of attachment of a Dacron patch), but in this study it was observed only microscopically and was located on the anterior surface of the capsule, adjacent to the area of calcification on the implant. In addition, crystals 100 times larger than those observed on the six saline implant capsules have been observed on the surface of gel implant capsules. A model is presented to explain the mechanism of calcification associated with breast implants and to explain the observed differences between saline-filled and gel-filled implants.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.250
Threshold uncertainty score0.765

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.198
Teacher spread0.178 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations29
Published2001
Admission routes1
Has abstractyes

Explore more

Same venuePlastic & Reconstructive SurgerySame topicBone Tissue Engineering MaterialsFrench-language works237,207