MétaCan
Menu
Back to cohort
Record W2093930083 · doi:10.1118/1.3378675

Absorption spectra time evolution of EBT‐2 model GAFCHROMIC™ film

2010· article· en· W2093930083 on OpenAlex
Slobodan Dević, Saad Aldelaijan, Huriyyah Mohammed, Nada Tomic, Liheng Liang, F DeBlois, Jan Seuntjens

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueMedical Physics · 2010
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsJewish General HospitalMcGill University
FundersAtomic Energy of Canada Limited
KeywordsMaterials scienceDosimetryAbsorbanceAbsorbed doseAbsorption (acoustics)OpticsSpectral lineNuclear medicinePhysicsMedicine

Abstract

fetched live from OpenAlex

PURPOSE: One of the major drawbacks of the current radiochromic film dosimetry protocols is the postirradiation waiting time. In this article, the authors study the postirradiation time evolution of the absorption spectrum of radiochromic EBT-2 GAFCHROMIC film model. METHODS: Postirradiation scanning times range from 3 min to 5 days and a dose range extends from 0 to 6 Gy. The authors compare the results of absorption spectra measurements for the latest GAFCHROMIC EBT-2 film model to the absorption spectra of the previous EBT GAFCHROMIC film model. The authors also describe a method that can establish the time error constraints on the postirradiation scanning time that will still provide an acceptable dose error for clinical applications if the protocol employing the shorter postirradiation scanning time is implemented in the clinic. RESULTS: The two film models experience the very same dose change in net absorbance with sensitivity of the latest EBT-2 model GAFCHROMIC film being slightly lower than its predecessor. The authors show that for two postirradiation scanning times of 30 min and 24 h, the 1% dose error can be achieved if the scanning time window is less than +/- 5 min and +/- 2 h, respectively. CONCLUSIONS: By comparing the resultant change in net absorbance between the latest EBT-2 and previous EBT GAFCHROMIC film models, the authors conclude that the addition of the yellow marker dye to the sensitive layer does not affect dosimetric properties of the latest film model. The authors also describe a procedure by which one can establish an acceptable time window around chosen postirradiation scanning time protocol that would provide an acceptable dose error for practical purposes.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.823
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.005
GPT teacher head0.253
Teacher spread0.248 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it