MétaCan
Menu
Back to cohort
Record W2095157399 · doi:10.1063/1.3563722

A miniature cell for gas solubility measurements in oils and bitumen

2011· article· en· W2095157399 on OpenAlexaff
Hooman Foroughi, Edgar Acosta, Masahiro Kawaji

Bibliographic record

VenueReview of Scientific Instruments · 2011
Typearticle
Languageen
FieldChemistry
TopicPetroleum Processing and Analysis
Canadian institutionsUniversity of Toronto
Fundersnot available
KeywordsSolubilityAsphaltMaterials scienceVolume (thermodynamics)ChromatographyAnalytical Chemistry (journal)ChemistryThermodynamicsComposite materialOrganic chemistryPhysics

Abstract

fetched live from OpenAlex

A miniature cell has been designed and constructed to measure gas solubility in crude oils and bitumen. The cell was made of stainless steel with a total internal volume of 1.835 cc and only an oil sample of 0.4 cc was required for one set of measurements at different pressures. By using this small cell, the waiting time for reaching equilibrium was less than 10 min. The technique was validated by measuring CO(2) gas solubility in two bitumen samples. The results were compared and found to be in very good agreement with available data. The apparatus was also used to study the effect of ashphaltene on CO(2) solubility in bitumen. It was shown that ashphaltene had a negligible effect on CO(2) solubility in bitumen.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.605
Threshold uncertainty score0.486

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.051
GPT teacher head0.272
Teacher spread0.221 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueReview of Scientific InstrumentsSame topicPetroleum Processing and AnalysisFrench-language works237,207