Frequency domain study of the relative effect of microstepping on the vibration spectra of stepping motors
Bibliographic record
Abstract
The design of a microprocessor-based programmable current source is described for application in the microstepping control of stepping motors. Tests were carried out to measure motor vibration in the time domain as a function of speed, step mode and current control. Two types of vibration sensor were designed and evaluated. In order to decouple the sensor from the motor, a unit was developed, based on optical coupling, which provides an output proportional to displacement. A second sensor utilized a micromachined silicon device to yield an output signal proportional to acceleration. A dual integrator/amplifier circuit was designed for use with the latter system to provide displacement, velocity, and acceleration outputs. The results are digitized and transformed into the frequency domain for further analysis. Frequency spectra are compared for variations in the motor control parameters. The results are of interest in stepping motor applications which require very delicate control of vibrations.>
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.002 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".