Fixed Mandibular Restorations on Three Early‐Loaded Regular Platform Brånemark Implants
Bibliographic record
Abstract
BACKGROUND: Originally, the Brånemark System was used as a two-stage surgical procedure. Comparable clinical results have made one-stage and early-loading concepts possible alternatives in the edentulous mandible. From the patient's point of view, the financial aspect of implant treatment is important. In an attempt to decrease financial burden, the reduction of surgical interventions and reduction of the number of implants could be considered. PURPOSE: This prospective multicenter study evaluated (1) the 1- and 3-year success rates of implants loaded within 1 month after one-stage surgery with a fixed 10- to 12-unit bridge on three regular platform Brånemark System implants in the mandible, (2) the outcome of the prosthetic treatment, and (3) the opinion of patients regarding the treatment procedure. MATERIALS AND METHODS: Of 20 patients, 19 received five implants in the mandible, of which three were functionally loaded with the one-stage technique (group 1). The loaded implants were inserted in a tripodal position, one implant in the symphysis and two located anterior of the mental foramen in the bicuspid area. Two additional implants were inserted for safety reasons but were not intended to be included in the restoration. These two additional implants served as either an unloaded one-stage control implant (group 2) or an unloaded control implant installed with the submerged technique (group 3). Immediately after surgery, the implants were loaded with a relined denture. The patients received a 10- to 12-unit prosthetic reconstruction an average 31 days (range, 4-53 d) after surgery. Implant stability was clinically checked at 3, 12, and 36 months. Radiographs were taken at corresponding follow-up visits to calculate bone-to-implant level and marginal bone resorption. RESULTS: Six of 60 functionally loaded implants (10%) and 3 of 20 prostheses (15%) failed within the first year. The cumulative implant failure rate in group 1, both after 1 and after 3 years, was 9.5%. No implant failure occurred in the control groups 2 and 3. The average marginal bone level measured at 1 and 3 years was 1.6 mm (SD = 0.8 mm) and 2.1 mm (SD = 0.2 mm), respectively, for group 1; 1.5 mm (SD = 1.3 mm) and 2.4 mm (SD = 0.6 mm), respectively, for group 2; 0.8 mm (SD = 1.4 mm) and 0.7 mm (SD = 0.9 mm), respectively, for group 3. CONCLUSIONS: The results of treatment using three regular platform Brånemark System implants supporting a fixed mandibular arch reconstruction were less favorable than the outcome that can be expected with a standard four- to six-implant with one-stage surgery.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.001 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.001 |
| Bibliometrics | 0.001 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.001 | 0.001 |
| Research integrity | 0.001 | 0.000 |
| Insufficient payload (model declined to judge) | 0.003 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".