Abstract
In medical diagnoses and treatments, e.g., the endoscopy, the dosage transition monitoring, it is often desirable to wirelessly track an object that moves through the human GI tract. In this paper, we present a magnetic localization and orientation system for such applications. This system uses a small magnet enclosed in the object to serve as excitation source. It does not require the connection wire and power supply for excitation signal. When the magnet moves, it establishes a static magnetic field around, whose intensity is related to the magnet's position and orientation. With the magnetic sensors, the magnetic intensities in some pre-determined spatial points can be detected, and the magnet's position and orientation parameters can be calculated based on an appropriate algorithm. Here, we propose a real-time tracking system built by Honeywell 3-axis magnetic sensors, HMC1053, as well as the computer sampling circuit. The results show that satisfactory tracking accuracy (average localization error is 3.3 mm) can be achieved using a sensor array with enough number of the 3-axis magnetic sensors.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".