MétaCan
Menu
← Back to cohort

Antibiotic lock: In vitro stability of vancomycin and four percent sodium citrate stored in dialysis catheters at 37°C

2009· article· en· W2097692759 on OpenAlexaffvenue
Marisa Battistella, Scott E. Walker, Shirley Law, Charmaine E. Lok

Bibliographic record

VenueHemodialysis International · 2009
Typearticle
Languageen
FieldHealth Professions
TopicCentral Venous Catheters and Hemodialysis
Canadian institutionsSunnybrook Health Science CentreUniversity of TorontoUniversity Health Network
Fundersnot available
KeywordsVancomycinMedicineSodium citrateHemodialysisDialysisSodiumSalineAntibioticsCatheterSurgeryChromatographyAnesthesiaStaphylococcus aureusChemistry

Abstract

fetched live from OpenAlex

Catheter-related bacteremia (CRB) is a major cause of morbidity and mortality especially among patients receiving hemodialysis (HD). Antibiotic lock therapy represents a promising technique in the treatment of CRB. Several studies have evaluated antibiotics in combination with heparin as an interdialytic locking solution as adjunctive therapy for CRB. The objective of this study was to evaluate the chemical stability of the vancomycin in 4% sodium citrate in HD catheters as an interdialytic lock. Vancomycin was prepared and diluted with sodium citrate 4% and stored in polyvinyl chloride syringes, 2 carbothane dialysis catheters (Hemostar) and 2 dual floating HD catheters (CardioMed). Syringes were stored at 4 degrees C or 23 degrees C and the catheters were stored in an incubator at 37 degrees C for 72 hours. Samples underwent daily chromatographic analysis and the luminal concentration of vancomycn was determined on study days 0, 1, and 3. When vancomycin is reconstituted with normal saline to achieve a concentration of 50 mg/mL, and then further diluted in 4% sodium citrate, to achieve concentrations of either 1 or 3 mg/mL, and then stored at 4 degrees C, room temperature, or 37 degrees C, solutions were observed to retain >92% of the initial concentration for the study period of 3 days. Based on the fastest degradation rate determined with 95% confidence interval, >90% is retained for 6.53 days. We conclude that vancomycin-4% citrate solutions stored in polyvinyl chloride syringes or HD catheters are not significantly affected by temperature or concentration within the 72 hours storage period. Therefore, these solutions can be anticipated to be suitable as a HD interdialytic antibiotic lock in standard HD catheters.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.035
GPT teacher head0.317
Teacher spread0.282 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2009
Admission routes2
Has abstractyes

Explore more

Same venueHemodialysis International→Same topicCentral Venous Catheters and Hemodialysis→French-language works237,207→