MétaCan
Menu
Back to cohort

Bioimpedance technique for monitoring cerebral artery stenosis in a 3D numerical model of the head

2011· article· en· W2098318219 on OpenAlexfundno aff
Ayelet Siegman, Shimon Abboud

Bibliographic record

VenueMedical Engineering & Physics · 2011
Typearticle
Languageen
FieldEngineering
TopicElectrical and Bioimpedance Tomography
Canadian institutionsnot available
FundersMcGill University
KeywordsStenosisSensitivity (control systems)Head (geology)Middle cerebral arteryInjectorStroke (engine)ArteryMedicineBiomedical engineeringCardiologyPhysicsIschemiaEngineeringElectronic engineeringGeology

Abstract

fetched live from OpenAlex

Insufficient blood supply to the brain causes a transient ischemic attack (TIA) or a stroke. One of the causes to insufficient blood supply is cerebral artery stenosis. In this study, the feasibility of bioimpedance for monitoring such stenosis was analyzed. Simulations were conducted on a realistic numerical model of the head, focusing on the left middle cerebral artery (LMCA). Tissues were assumed to act as linear isotropic volume conductors, and the quasi-static approximation was applied. Electrical potentials were calculated by solving Poisson's equation, using the finite volume method (FVM) and the successive over relaxation (SOR) method. The best sensitivity found was 0.471 μV/% stenosis, using this electrode configuration: one injector near the left eye and the other injector near the right ear, one measurement position near the left eye and the other one in the right ear, keeping a distance of at least 2.5 cm between measurement and injection positions. The maximal sensitivity achieved in the numerical model under the applied assumptions supports the feasibility of bioimpedance technique for monitoring cerebral artery stenosis. However, according to sensitivity [1/m(4)] maps, calculated for the preferable electrode configurations, the measurements' specificity to the stenosis degree might be inadequate and should be further studied.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.762
Threshold uncertainty score0.626

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.215
Teacher spread0.195 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueMedical Engineering & PhysicsSame topicElectrical and Bioimpedance TomographyFrench-language works237,207