MétaCan
Menu
Back to cohort

Abutment Screw Loosening and Bending Resistance of External Hexagon Implant System after Lateral Cyclic Loading

2004· article· en· W2098662371 on OpenAlexvenueno aff
Ameen Khraisat, Osama Abu‐Hammad, Najla Dar‐Odeh, Awni M. Al-Kayed

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2004
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsImplantMaterials scienceAbutmentBendingOrthodonticsUniversal testing machineDental AbutmentsCyclic stressDentistryStructural engineeringComposite materialMedicineUltimate tensile strengthEngineeringSurgery

Abstract

fetched live from OpenAlex

BACKGROUND: Rigorous efforts to reduce the recurrence of abutment screw loosening in single-tooth implant restorations have recently been made. However, the behavior of the implant/abutment joint components with respect to critical bending force is still unclear. PURPOSE: This study investigated the effect of different cyclic loading periods on abutment screw loosening and bending resistance of a single-tooth external hexagon implant system. MATERIAL AND METHODS: Fifteen Brånemark implant assemblies were divided equally into groups A, B, and C. Each assembly consisted of a Brånemark System Mk IV 4 x 10 mm implant (Nobel Biocare AB, Gothenburg, Sweden) mounted in a brass block, a CeraOne 3 mm abutment (Nobel Biocare AB), and an experimental cement-retained superstructure. For groups A and B a cyclic load of 50 N was applied centrally and perpendicular to the long axis of the implant. Targets of 1.0 x 10(6) cycles (40 months of simulated function) and 0.5 x 10(6) cycles (20 months of simulated function) were defined for groups A and B, respectively. Group C (control) was left unloaded for the same loading time period as was group B. Reverse torque was recorded before and after loading, and the difference was calculated. After cyclic loading, specimens were mounted in a testing machine, and the yielding and bending strengths were measured. The data were analyzed with one-way analysis of variance and were compared by means of the Tukey test (p < .05). RESULTS: There were statistically significant differences (p < .001) in the reverse torque difference values of group A ([-5.6 to -3.4] +/- 0.86 Ncm) as compared to those of group B ([-2.4 to -1.6] +/- 0.32 Ncm) and group C ([-0.7 to 0.0] +/- 0.26 Ncm). Likewise, group B showed a significant difference compared to group C (p = .002). On the other hand there was no statistically significant difference in the mean values among the test groups in regard to the yielding and bending strengths (p >.050). CONCLUSION: Within the limitations of this study, long-term fatigue significantly affected the reverse torque values under centric lateral load (p <.001) whereas it had no significant effect on the resistance of the implant/abutment joint to static bending.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.071
GPT teacher head0.423
Teacher spread0.351 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations51
Published2004
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related ResearchSame topicDental Implant Techniques and OutcomesFrench-language works237,207