MétaCan
Menu
Back to cohort

First Experience With Direct Factor Xa Inhibition in Patients With Stable Coronary Disease

2002· article· en· W2099094229 on OpenAlexaff
Christopher K. Dyke, Richard C. Becker, Neal S. Kleiman, Judith S. Hochman, Edwin G. Bovill, A. Michael Lincoff, Gary Gerstenblith, Vladimír Džavík, Laura H. Gardner, Vic Hasselblad, Linda A. Zillman, Yoshimasa Shimoto, Thomas Robertson, Satoshi Kunitada, Paul W. Armstrong, Robert A. Harrington

Bibliographic record

VenueCirculation · 2002
Typearticle
Languageen
FieldMedicine
TopicBlood Coagulation and Thrombosis Mechanisms
Canadian institutionsUniversity of Alberta
FundersNIH Clinical Center
KeywordsMedicinePartial thromboplastin timePharmacodynamicsProthrombin timePharmacokineticsBolus (digestion)CreatinineInternal medicineAnticoagulantCoronary artery diseaseRenal functionProthrombin complex concentrateGastroenterologyPlateletUrologyPharmacologyAtrial fibrillationWarfarin

Abstract

fetched live from OpenAlex

BACKGROUND: Thrombin generation is critical to the formation of an arterial thrombus after rupture of an atherosclerotic plaque. In patients with stable coronary disease receiving standard medical therapy, we evaluated the pharmacokinetics, pharmacodynamics, and safety profile of DX-9065a, a novel small-molecule anticoagulant that directly, selectively, and reversibly inhibits factor Xa. METHODS AND RESULTS: In a double-blind trial, 73 patients (median age, 63 years; 29% women) were randomly assigned to receive a fixed-dose intravenous bolus, followed by a 72-hour infusion of placebo or 1 of 4 weight-adjusted regimens of DX-9065a. Plasma samples were collected during infusion and a 24-hour elimination period. Only minor bleeding occurred, predominantly ecchymoses at infusion sites, and its incidence did not differ significantly among the groups, including placebo. Median hemoglobin, platelet count, serum creatinine level, and liver function tests did not change significantly from baseline during infusion or elimination. Significant predictors of pharmacokinetic response included infusion dose and weight. At 60 hours into the DX-9065a infusion, plasma drug levels correlated strongly with anti-factor Xa activity (r=0.97), prothrombin time (r=0.77), and international normalized ratio (r=0.72) but less so with activated partial thromboplastin time (r=0.56; all P<0.001). CONCLUSIONS: This is the first study of a selective, reversible, and direct small-molecule factor Xa inhibitor in patients with stable coronary disease. These data lay the foundation for further investigation of factor Xa inhibitors in the treatment of patients with coronary atherothrombosis.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Non-randomized trial · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.010

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.224
Teacher spread0.201 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNon-randomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations63
Published2002
Admission routes1
Has abstractyes

Explore more

Same venueCirculationSame topicBlood Coagulation and Thrombosis MechanismsFrench-language works237,207