Abstract

fetched live from OpenAlex

Vascular access ports are used widely in the administering of drugs for radiation oncology patients. Their dosimetric effect on radiation therapy delivery in photon beams has not been rigorously established. In this work the effects on external beam fields when any of a variety of vascular access ports is included in the path of a high energy beam are studied. This medical physics study specifically identifies side-scatter and back-scatter consequences as well as attenuation effects. The study was divided into two parts: Firstly, a total of 18 ports underwent extended HU range CT scanning followed by 3-D computer treatment planning, where independent homogeneity and heterogeneity plans were created for photon beams of energy 6 MV and 18 MV using a Pencil Beam Convolution (PBC) algorithm. Dose points were analyzed at locations all around each device. A total of 1,440 points were reviewed in this section of the study. Secondly, a mock-up of the largest vascular access port was created in the treatment planning workspace for further investigation with alternative treatment planning algorithms. Plans were generated identically to the above and compared to the results of dose computation between the Pencil Beam Convolution algorithm, the Analytical Anisotropic Algorithm (AAA), and the EGSnrc Monte Carlo algorithm with user code DOSRZnrc (MC). A total of 300 points were reviewed in this part of the study. It was conclusive that ports with more bulky construction and those with partial metal composition create the largest changes. Similar effects are seen for similar port configurations. Considerable differences between the PBC and AAA in comparison to MC are noted and discussed. By thorough examination of planning system results, the presented vascular access ports may now be ranked according to the greatest amount of change exhibited within a treatment planning system. Effects of backscatter, lateral scatter and attenuation are up to 5.0%, 3.4% and 16.8% for 6 MV and 7.0%, 7.7% and 7.2% for 18 MV respectively.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.981
Threshold uncertainty score0.704

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.372
Teacher spread0.353 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations18
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Applied Clinical Medical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207