MétaCan
Menu
Back to cohort
Record W2099888191 · doi:10.1111/acem.12577

Classification of Cardiopulmonary Resuscitation Chest Compression Patterns: Manual Versus Automated Approaches

2015· article· en· W2099888191 on OpenAlexafffund
Henry E. Wang, Robert H. Schmicker, Heather Herren, Siobhan P. Brown, John P. Donnelly, Randal Gray, Sally Ragsdale, A P Gleeson, Adam Byers, Jamie Jasti, Christina Aguirre, Pam Owens, Joe Condle, Brian G. Leroux

Bibliographic record

VenueAcademic Emergency Medicine · 2015
Typearticle
Languageen
FieldMedicine
TopicCardiac Arrest and Resuscitation
Canadian institutionsOttawa HospitalProvidence Health CareSaint Paul UniversityUniversity of TorontoSt. Michael's HospitalUniversity of Ottawa
FundersNational Heart, Lung, and Blood InstituteCanadian Institutes of Health ResearchAgency for Healthcare Research and Quality
KeywordsMedicineCardiopulmonary resuscitationChest painCompression (physics)Confidence intervalKappaResuscitationRadiologyInternal medicineSurgery

Abstract

fetched live from OpenAlex

OBJECTIVES: New chest compression detection technology allows for the recording and graphical depiction of clinical cardiopulmonary resuscitation (CPR) chest compressions. The authors sought to determine the inter-rater reliability of chest compression pattern classifications by human raters. Agreement with automated chest compression classification was also evaluated by computer analysis. METHODS: This was an analysis of chest compression patterns from cardiac arrest patients enrolled in the ongoing Resuscitation Outcomes Consortium (ROC) Continuous Chest Compressions Trial. Thirty CPR process files from patients in the trial were selected. Using written guidelines, research coordinators from each of eight participating ROC sites classified each chest compression pattern as 30:2 chest compressions, continuous chest compressions (CCC), or indeterminate. A computer algorithm for automated chest compression classification was also developed for each case. Inter-rater agreement between manual classifications was tested using Fleiss's kappa. The criterion standard was defined as the classification assigned by the majority of manual raters. Agreement between the automated classification and the criterion standard manual classifications was also tested. RESULTS: The majority of the eight raters classified 12 chest compression patterns as 30:2, 12 as CCC, and six as indeterminate. Inter-rater agreement between manual classifications of chest compression patterns was κ = 0.62 (95% confidence interval [CI] = 0.49 to 0.74). The automated computer algorithm classified chest compression patterns as 30:2 (n = 15), CCC (n = 12), and indeterminate (n = 3). Agreement between automated and criterion standard manual classifications was κ = 0.84 (95% CI = 0.59 to 0.95). CONCLUSIONS: In this study, good inter-rater agreement in the manual classification of CPR chest compression patterns was observed. Automated classification showed strong agreement with human ratings. These observations support the consistency of manual CPR pattern classification as well as the use of automated approaches to chest compression pattern analysis.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.043
metaresearch head score (Gemma)0.097
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.043
Threshold uncertainty score0.226

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0430.097
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0050.002
Science and technology studies0.0010.001
Scholarly communication0.0020.002
Open science0.0010.002
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.157
GPT teacher head0.380
Teacher spread0.223 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2015
Admission routes2
Has abstractyes

Explore more

Same venueAcademic Emergency MedicineSame topicCardiac Arrest and ResuscitationFrench-language works237,207