MétaCan
Menu
Back to cohort
Record W2101119015 · doi:10.1111/clr.12640

Electronic assessment of peri‐implant mucosal esthetics around three implant–abutment configurations: a randomized clinical trial

2015· article· en· W2101119015 on OpenAlexaff
Christopher A. Barwacz, Clark M. Stanford, Ursula A. Diehl, Fang Qian, Lyndon F. Cooper, J.S. Feine

Bibliographic record

VenueClinical Oral Implants Research · 2015
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsMcGill University
FundersDENTSPLY Implants
KeywordsAbutmentDentistryImplantPeriMedicineRandomized controlled trialDental AbutmentsOrthodonticsEngineeringSurgeryInternal medicine

Abstract

fetched live from OpenAlex

OBJECTIVES: To objectively assess the influence that three different implant-abutment interface designs had on peri-implant mucosal esthetics at 1 year post-implant placement via the pink esthetic score (PES). Additionally, to demonstrate the novel employment of a tablet-based digital imaging format to reliably assess and score clinical images as part of a multicenter clinical trial according to PES criteria. MATERIALS AND METHODS: Adult subjects (n = 141) with healed tooth-bound edentulous sites in the anterior maxilla as well as first premolar region were randomized to receive one of three different implant-abutment interface designs (conical interface = CI; flat-to-flat interface = FI; or platform switch interface = PS). Immediate provisionalization was performed with prefabricated titanium abutments, with definitive custom CAD/CAM zirconia abutments and all-ceramic cement-based crowns being delivered 12-week post-implant placement. Bilateral (anterior sites) or unilateral (premolar sites) digital clinical photographs were made at 1, 3, 6, and 12 months post-implant placement. Five calibrated faculty evaluators of different clinical backgrounds scored images during a 4-week timeframe on a standardized, tablet-based, digital imaging format. RESULTS: Six hundred and forty-nine clinical photographs were evaluated resulting in a total of 3245 sum PES values and 22,715 individual PES values. Faculty evaluator intra- and inter-rater reliability was found to be "strong" (ICC = 0.84) and "substantial" (ICC = 0.64), respectively, demonstrating repeatability of both the PES, evaluator calibration, and standardization of tablet-based scoring. All implant-abutment interface groups demonstrated significant improvements in mean sum PESs up to 1 year, with the largest improvement between restoration delivery and 6 months. No significant differences were found between groups in mean sum PESs both for individual study visits as well as for changes between study visits. CONCLUSIONS: No significant differences in mean sum PESs were found between subjects randomized to three different implant-abutment interfaces. However, significant differences were found as a function of time for all three groups, with the largest improvement in mean sum PESs occurring between definitive abutment and restoration delivery and 6 months. Use of electronic, tablet-based digital imaging scoring formats represents a novel and repeatable methodology for scoring PES images in large, multicenter clinical trials.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.035
metaresearch head score (Gemma)0.005
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch, Meta-epidemiology (narrow), Research integrity
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.200
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0350.005
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0030.001
Bibliometrics0.0000.001
Science and technology studies0.0000.002
Scholarly communication0.0000.000
Open science0.0010.001
Research integrity0.0010.003
Insufficient payload (model declined to judge)0.0000.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.439
GPT teacher head0.602
Teacher spread0.163 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations19
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueClinical Oral Implants ResearchSame topicDental Implant Techniques and OutcomesFrench-language works237,207