MétaCan
Menu
Back to cohort
Record W2101232701 · doi:10.1177/2048872614549102

Acute intraoperative effect of intravenous amiodarone on right ventricular function in patients undergoing valvular surgery

2014· article· en· W2101232701 on OpenAlexafffund
André Denault, Yanick Beaulieu, Pierre Couture, François Haddad, Yanfen Shi, Pierre Pagé, Sylvie Lévesque, Jean‐Claude Tardif, Jean Lambert

Bibliographic record

VenueEuropean Heart Journal Acute Cardiovascular Care · 2014
Typearticle
Languageen
FieldMedicine
TopicCardiac, Anesthesia and Surgical Outcomes
Canadian institutionsHôpital du Sacré-Cœur de MontréalUniversité de MontréalCentre Hospitalier de l’Université de MontréalMontreal Heart Institute
FundersFonds de Recherche du Québec - SantéFondation Institut de Cardiologie de Montréal
KeywordsMedicineCardiologyAmiodaroneInternal medicineCardiac indexDoppler echocardiographyHemodynamicsPulmonary arteryDiastoleCentral venous pressureMitral valveAnesthesiaPlaceboBlood pressureCardiac outputAtrial fibrillationHeart rate

Abstract

fetched live from OpenAlex

BACKGROUND: Amiodarone is commonly used in the acute care setting. However the acute hemodynamic and echocardiographic effect of intravenous amiodarone administered intraoperatively on right ventricular (RV) systolic and diastolic function using transesophageal echocardiography (TEE) has not been described. METHODS: The study design was a randomized controlled trial in elective cardiac surgical patients undergoing valvular surgery. Patients received an intravenous loading dose of 300 mg of either amiodarone or placebo in the operating room, followed by an infusion of 15 mg/kg for two days. Hemodynamic profiles, echocardiographic measurement of RV and left ventricular (LV) dimensions, Doppler interrogation of tricuspid and mitral valve, hepatic and pulmonary venous flow combined with tissue Doppler imaging of the tricuspid and mitral valve annulus were obtained before and after bolus. RESULTS: Although more patients in the placebo group had chronic obstructive lung disease (14 vs 6, p=0.05) and diabetes (14 vs 5; p=0.0244), there was no difference in terms of baseline hemodynamic, 2D and Doppler variables. After bolus, a significant increase in pulmonary artery pressure, central venous pressure and pulmonary vascular resistance index (p<0.05) was observed in the amiodarone group with reduction in systolic to diastolic (S/D) ratio of the hepatic (p=0.0247) and pulmonary venous (p=0.0052) velocity. CONCLUSION: Acute administration of amiodarone is associated with alteration in RV diastolic properties and has minimal negative inotropic effect on RV systolic function in cardiac surgical patients with valvular disease.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.108
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0020.004
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.221
Teacher spread0.214 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2014
Admission routes2
Has abstractyes

Explore more

Same venueEuropean Heart Journal Acute Cardiovascular CareSame topicCardiac, Anesthesia and Surgical OutcomesFrench-language works237,207