MétaCan
Menu
Back to cohort
Record W2101606064 · doi:10.1002/adfm.201001762

Nanotechnology‐Enabled Closed Loop Insulin Delivery Device: In Vitro and In Vivo Evaluation of Glucose‐Regulated Insulin Release for Diabetes Control

2010· article· en· W2101606064 on OpenAlexafffund
Cláudia R. Gordijo, Khajag Koulajian, Adam J. Shuhendler, Leonardo D. Bonifacio, Hui Huang, Simon Chiang, Geoffrey A. Ozin, Adria Giacca, Xiao Yu Wu

Bibliographic record

VenueAdvanced Functional Materials · 2010
Typearticle
Languageen
FieldPharmacology, Toxicology and Pharmaceutics
TopicAdvanced Drug Delivery Systems
Canadian institutionsCanada Research ChairsUniversity of Toronto
FundersCanadian Institutes of Health ResearchNatural Sciences and Engineering Research Council of CanadaCanada Research ChairsGovernment of Canada
KeywordsInsulinGlucose oxidasePEGylationMaterials scienceIn vivoGlucose transporterBiocompatibilityInternal medicineBiosensorNanotechnologyMedicineBiology

Abstract

fetched live from OpenAlex

Abstract Recently, a new multifunctional, bio‐inorganic nanocomposite membrane with the ability to self‐regulate the release of insulin in response to blood glucose (BG) levels was reported. Herein, the application of this material as part of a small, implantable, closed‐loop insulin delivery device designed to continuously monitor BG concentrations and regulate insulin release is proposed. The insulin delivery device consists of a nanocomposite glucose‐responsive plug covalently bound to an insulin reservoir made of surface‐modified silicone. The plug is prepared with crosslinked bovine serum albumin (BSA) and enzymes (glucose oxidase (GOx) and catalase (CAT)), pH‐responsive hydrogel nanoparticles, and multifunctional MnO2 nanoparticles. The plug functions both as a glucose sensor and controlled delivery unit to release higher rates of insulin from the reservoir in response to hyperglycemic BG levels and basal insulin rates at normal BG concentration. The surfaces of the device are modified by silanization followed by PEGylation to ensure its safety and biocompatibility and the stability of encased insulin. Our results show that insulin release can be modulated in vitro in response to glucose concentrations. In vivo experiments show that the glycemia of diabetic rats can be controlled with implantation of the prototype device. The glucose‐responsiveness of the device is also demonstrated by rapid drop in BG level after challenging diabetic rats with bolus injection of glucose solution. In addition, it is demonstrated that surface PEGylation of the device is necessary for reducing the immune response of the host to the implanted foreign object and maintaining insulin stability and bioactivity. With this molecular architecture and the bio‐inorganic nanocomposite plug, the device has the ability to maintain normal BG levels in diabetic rats.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.000
Threshold uncertainty score0.002

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.041
GPT teacher head0.346
Teacher spread0.305 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations124
Published2010
Admission routes2
Has abstractyes

Explore more

Same venueAdvanced Functional MaterialsSame topicAdvanced Drug Delivery SystemsFrench-language works237,207