A 1‐Year Prospective Study on Co‐Axis® Implants Immediately Loaded with a Full Ceramic Crown
Bibliographic record
Abstract
INTRODUCTION: The Co-Axis implant (Southern Implants, Irene, South Africa) has a 12-degree angle in the implant neck to overcome angulation problems. AIM: To examine bone loss, peri-implant health, and aesthetical outcome after 1-year follow-up. MATERIALS AND METHODS: Fifteen single implants were placed in 14 patients in the premaxilla and immediately loaded with a screw-retained full ceramic crown. Periapical radiographs and standardized photographs were taken to determine bone loss and soft tissue changes. Plaque and bleeding levels were assessed. Patients' satisfaction was measured using the Oral Health Impact Profile-14 questionnaire. RESULTS: After 1 year, all implants survived and mean bone loss was 1.20 mm, with no significant changes after 6 months. Plaque levels were low and no significant changes were observed. Bleeding levels decreased during the initial 3 months, but were constant thereafter. Before final torqueing was performed after 6 months, four cases of screw loosening occurred. Also, one crown had a piece of porcelain chipped off. Patients reported an overall increase in well-being. A mean midfacial recession of 0.37 mm was observed. The mesial papilla showed a slight increase of 0.14 mm, while the distal papilla decreased 0.35 mm. CONCLUSION: With 100% survival and stable bone levels after 6 months, the Co-Axis implant showed a good clinical outcome when immediately loaded. The use of a full ceramic crown as a first and final restoration resulted in a good aesthetic outcome with few changes in papilla fill, although midfacial soft tissue was stable only after 1 year.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.002 | 0.002 |
| Meta-epidemiology (narrow) | 0.001 | 0.001 |
| Meta-epidemiology (broad) | 0.002 | 0.002 |
| Bibliometrics | 0.001 | 0.001 |
| Science and technology studies | 0.001 | 0.001 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.001 | 0.001 |
| Research integrity | 0.002 | 0.001 |
| Insufficient payload (model declined to judge) | 0.002 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".