MétaCan
Menu
Back to cohort
Record W2104193361 · doi:10.2196/ijmr.2824

Remote Monitoring for Implantable Defibrillators: A Nationwide Survey in Italy

2013· article· en· W2104193361 on OpenAlexvenueno aff
Mario Luzi, Antonio De Simone, Loira Leoni, Claudia Amellone, Ennio Pisanò, Stefano Favale, Massimo Iacoviello, R. Luise, Maria Grazia Bongiorni, Giuseppe Stabile, Vincenzo La Rocca, Franco Folino, Alessandro Capucci, Antonio D’Onofrio, Francesco Accardi, Sergio Valsecchi, Gianfranco Buia

Bibliographic record

VenueInteractive Journal of Medical Research · 2013
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsnot available
FundersBoston Scientific Corporation
KeywordsMedical emergencyMedicine

Abstract

fetched live from OpenAlex

BACKGROUND: Remote monitoring (RM) permits home interrogation of implantable cardioverter defibrillator (ICD) and provides an alternative option to frequent in-person visits. OBJECTIVE: The Italia-RM survey aimed to investigate the current practice of ICD follow-up in Italy and to evaluate the adoption and routine use of RM. METHODS: An ad hoc questionnaire on RM adoption and resource use during in-clinic and remote follow-up sessions was completed in 206 Italian implanting centers. RESULTS: The frequency of routine in-clinic ICD visits was 2 per year in 158/206 (76.7%) centers, 3 per year in 37/206 (18.0%) centers, and 4 per year in 10/206 (4.9%) centers. Follow-up examinations were performed by a cardiologist in 203/206 (98.5%) centers, and by more than one health care worker in 184/206 (89.3%) centers. There were 137/206 (66.5%) responding centers that had already adopted an RM system, the proportion of ICD patients remotely monitored being 15% for single- and dual-chamber ICD and 20% for cardiac resynchronization therapy ICD. Remote ICD interrogations were scheduled every 3 months, and were performed by a cardiologist in 124/137 (90.5%) centers. After the adoption of RM, the mean time between in-clinic visits increased from 5 (SD 1) to 8 (SD 3) months (P<.001). CONCLUSIONS: In current clinical practice, in-clinic ICD follow-up visits consume a large amount of health care resources. The results of this survey show that RM has only partially been adopted in Italy and, although many centers have begun to implement RM in their clinical practice, the majority of their patients continue to be routinely followed-up by means of in-clinic visits.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.029
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.190
Threshold uncertainty score0.979

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0060.029
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.144
GPT teacher head0.488
Teacher spread0.344 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueInteractive Journal of Medical ResearchSame topicCardiac pacing and defibrillation studiesFrench-language works237,207