MétaCan
Menu
Back to cohort
Record W2104454533 · doi:10.1186/1743-0003-5-2

An instrumented cylinder measuring pinch force and orientation

2008· article· en· W2104454533 on OpenAlexafffund
Daniel Bourbonnais, Victor Frak, Jean-François Pilon, Michel Goyette

Bibliographic record

VenueJournal of NeuroEngineering and Rehabilitation · 2008
Typearticle
Languageen
FieldNeuroscience
TopicMotor Control and Adaptation
Canadian institutionsUniversité du Québec à MontréalUniversité de MontréalCentre for Interdisciplinary Research in Rehabilitation
FundersCanadian Institutes of Health ResearchCentre for Interdisciplinary Research in Rehabilitation
KeywordsPinchCylinderPerpendicularMechanicsTorquePhysicsBall (mathematics)AmplitudeNormal forceGeometryOpticsMathematics

Abstract

fetched live from OpenAlex

BACKGROUND: The function of a cylinder allowing simultaneous measurements of the opposition axis of the index finger and thumb of the hand and the magnitude of pinch force is described. METHODS: The apparatus is made of two half-cylinders that are bonded together through a 6-axis force/torque sensor and allows the measurement of 3D orthogonal forces and moments of force. The amplitude of the pinch force exerted on the cylinder by the fingers is defined as the resultant of the forces in the different axes. A software program was developed to measure the barycentre of the forces on the instrumented cylinder, allowing calculation of the angle of the opposition axis between the fingers and the location of the resulting pinch force on the cylinder, assuming that the pinch or grip forces are co-linear through the center of the cylinder. In order to assess the validity and reliability of the measurements, the cylinder was mounted on a milling table and seven calibrated weights (from 100 to 500 g) were successively applied perpendicularly to a 9*9 matrix of sites separated by 1 cm. With the exception of the extreme lateral parts of the cylinder, the dispersion of the calculated vertical position of the resulting force was always within 1 mm of the application point, suggesting a high reliability of these measurements. In addition, the errors in the angles of the applied force were calculated and found to be less than 2 degree with no clear patterns of variation across the different locations of the cylinder. RESULTS: The usefulness of the cylinder is demonstrated by evaluating the pinch force and the opposition axis in six healthy subjects lifting the cylinder from the table using three different orientations of their right hand. The magnitude of the grip force was not significantly different across orientations (45, 22 and -22 degrees relative to the midline of the subject) suggesting that force grip is controlled. CONCLUSION: From these results, it has been concluded that the cylinder is a valid, reliable and precise instrument that may prove useful for evaluating opposition axis and grip force in healthy and pathological populations.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.003
Threshold uncertainty score0.010

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.004
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.001
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.230
Teacher spread0.210 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2008
Admission routes2
Has abstractyes

Explore more

Same venueJournal of NeuroEngineering and RehabilitationSame topicMotor Control and AdaptationFrench-language works237,207