MétaCan
Menu
Back to cohort

A Prospective Multicenter Clinical Trial Comparing One‐ and Two‐Stage Titanium Screw‐Shaped Fixtures with One‐Stage Plasma‐Sprayed Solid‐Screw Fixtures

2000· article· en· W2105533059 on OpenAlexvenueno aff
William Becker, Burton E. Becker, A. Ricci, O Bahat, Edwin S. Rosenberg, Louis F. Rose, M Handelsman, Hilton Israelson

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2000
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsImplantMedicineDentistryStage (stratigraphy)TitaniumMulticenter studyProspective cohort studySurvival rateSurgeryMaterials scienceRandomized controlled trialMetallurgy

Abstract

fetched live from OpenAlex

BACKGROUND: Brånemark fixtures were originally placed in two stages, whereas titanium plasma-sprayed (TPS) solid-screws are placed in one stage. Long-term survival rates for both types of implants are excellent. Excellent survival rates have also been reported for machined screw-shaped (MS) titanium implants placed in one stage. A small number of studies have compared different implant systems and methods of implant placement. PURPOSE: The purpose of this study is to report clinical outcomes from a prospective longitudinal, multicenter study comparing Brånemark MS fixtures (Nobel Biocare, Yorba Linda, California, USA) placed in either one or two stages with a one-stage TPS system (ITI Straumann, Waldenburg, Switzerland). METHODS: A protocol was designed to compare implant survival rates, changes in crestal bone for titanium MS fixtures placed in one and two stages, and plasma-sprayed solid-screw fixtures placed in one surgical stage. Twenty-nine patients ranging in age from 24 to 82 years received MS fixtures in one stage. The average age for males was 58 years (n = 11), whereas the ages for females (n = 18) ranged from 15 to 84 years (average 58 years). Twenty-nine patients received machined titanium fixtures placed in two stages. There were 20 females ranging in age from 23 to 74 years (average 54 years) and 9 females ranging from 24 to 74 years (average 46 years). Twenty-five patients received TPS fixtures. There were 15 males, ranging in age from 57 to 79 (average 70), and 10 females, ranging in age from 40 to 83 years (average 62 years). Bone quality and quantity were determined from radiographs and during site preparation. Patient age, sex, location of implant placement according to jaw, length of fixtures, and number of lost fixtures were entered onto computer code sheets and continuously entered into a locked computer system. For one- and two-stage MS fixtures, nonstandardized periapical radiographs were taken at abutment connection and follow-up. Solid screws were x-rayed at prostheses connection and follow-up. The average time between implant restoration and radiographic follow-up was 15 months. The x-rays were scanned into a computer, and a program designed to measure radiographs was used to determine changes in crestal bone. Measurements for one- and two-stage MS fixtures were made from the top of the implant shoulder to the first bone to implant contact mesial and distally. Plasma-sprayed screws were measured from the bottom of the implant to the coronal most bone to implant contacts mesial and distally. Mesial-distal radiographic measurements were averaged and changes were compared using the t-test for related samples. RESULTS: This report presents data from the 2- to 3-year follow-up examinations. Twenty-nine patients received 80 one-stage MS fixtures. Between 0 and 1 year, two fixtures were lost, resulting in a 97.5% cumulative survival rate (CSR). The CSR remained unchanged through the 2- to 3-year follow-up. Twenty-eight patients received 78 two-stage MS fixtures. One implant was lost prior to loading and two were lost between 0- and 1-year follow-up, yielding a 96.2% CSR at the end of 1 year. The CSR remained unchanged through the 2- to 3-year follow-up. Twenty-three patients received 78 solid-screw plasma-sprayed screws. One implant was lost prior to loading and one between the 0- to 1-year follow-up, accounting for a 97.4% CSR at the 2- to 3-year follow-up. Changes in bone crest measurements for one-stage titanium threaded fixtures were insignificant (-0.11 mm, p = .08, maxillary; 0.07 mm, p = .42, mandibular). For two-stage MS fixtures, crestal bone loss was insignificant in maxillae (-0.16 mm, p = .92) and significant in mandibles (-0.43 mm, p = .000). There was significant bone loss for TPS implants in maxillae and mandibles (maxillae, 1.31 mm, p = .04; mandibles, 0.98 mm, p = .000). CONCLUSIONS: Cumulative survival rates for MS fixtures placed in one and two stages as well as one-stage TPS screws up to the 2- to 3-year follow-up examination were similar, indicating excellent clinical results. Radiographic measurements for changes in crestal bone loss were clinically insignificant for fixtures placed in one stage. For two-stage fixtures, maxillary changes were insignificant, whereas mandibular bone loss was statistically significant but clinically insignificant. Changes in crestal bone loss for TPS implants were statistically significant.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.005
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.005
Threshold uncertainty score0.027

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0050.004
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0030.003
Bibliometrics0.0010.001
Science and technology studies0.0010.002
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0050.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.180
GPT teacher head0.488
Teacher spread0.307 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations121
Published2000
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related ResearchSame topicDental Implant Techniques and OutcomesFrench-language works237,207