MétaCan
Menu
← Back to cohort

Hydration abnormalities in Nigerian patients on chronic hemodialysis

2007· article· en· W2105549931 on OpenAlexvenueno aff
Antonios H. Tzamaloukas, Aideloje Onime, Emmanuel I. Agaba, Dorothy J. VanderJagt, Irene Ma, A. Lopez, R.A. Tzamaloukas, Robert H. Glew

Bibliographic record

VenueHemodialysis International · 2007
Typearticle
Languageen
FieldMedicine
TopicDialysis and Renal Disease Management
Canadian institutionsnot available
Fundersnot available
KeywordsBioelectrical impedance analysisBody waterMedicineHemodialysisAnthropometryDialysisExtracellular fluidKidney diseaseBody weightCardiologyInternal medicineUrologySurgeryBody mass indexExtracellularChemistry

Abstract

fetched live from OpenAlex

The state of hydration affects the outcomes of chronic dialysis. Bioelectrical impedance analysis (BIA) provides estimates of body water (V), extracellular volume (ECFV), and fat-free mass (FFM) that allow characterization of hydration. We compared single-frequency BIA measurements before and after 14 hemodialysis sessions in 10 Nigerian patients (6 men, 4 women; 44+/-7 years old) with clinical evaluation (weight removed during dialysis, presence of edema) and with estimates of body water obtained by the Watson, Chertow, and Chumlea anthropometric formulas. Predialysis and postdialysis values of body water did not differ between BIA and anthropometric estimates. However, only the BIA estimate of the change in body water during dialysis (-0.8+/-2.9 L) did not differ from the corresponding change in body weight (-1.3+/-3.0 kg), while anthropometric estimates of the change in body water were significantly lower, approximately one-third of the change in weight. Bioelectrical impedance analysis correctly detected the intradialytic change in body water content (the ratio V/Weight) in 79% of the cases, while anthropometric formula estimates of the same change were erroneous in each case. Compared with patients with clinical postdialysis euvolemia (n=7), those with postdialysis edema (n=5) had higher values of postdialysis BIA ratios V/FFM (0.77+/-0.01 vs. 0.72+/-0.03, p<0.01) and ECFV/V (0.53+/-0.02 vs. 0.47+/-0.06, p<0.05), respectively. Bioelectrical impedance analysis appeared to underestimate body water and extracellular volume in a patient with massive ascites and bilateral pleural effusions. Anthropometric formulas are not appropriate for evaluating the state of hydration in patients on chronic hemodialysis. In contrast, BIA provides estimates of hydration agreeing with clinical estimates in the same patients, although it tends to underestimate body water and extracellular volume in patients with large collections of fluid in central body cavities.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.012

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0010.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.263
Teacher spread0.253 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueHemodialysis International→Same topicDialysis and Renal Disease Management→French-language works237,207→