An Integrated Array of Microfluidic Oxygenators as a Neonatal Lung Assist Device: In Vitro Characterization and In Vivo Demonstration
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
A miniaturized oxygenator device that is perfused like an artificial placenta via the umbilical vessels may have significant potential to save the lives of newborns with respiratory insufficiency. Recently we presented the concept of an integrated modular lung assist device (LAD) that consists of stacked microfluidic single oxygenator units (SOUs) and demonstrated the technical details and operation of SOU prototypes. In this article, we present a LAD prototype that is designed to accommodate the different needs of term and preterm infants by permitting changing of the number of parallel-stacked microfluidic SOUs according to the actual body weight. The SOUs are made of polydimethylsiloxane, arranged in parallel, and connected though 3D-printed polymeric interconnects to form the LAD. The flow characteristics and the gas exchange properties were tested in vitro using human blood. We found that the pressure drop of the LAD increased linearly with flow rate. Gas exchange rates of 2.4-3.8 μL/min/cm(2) (0.3-0.5 mL/kg/min) and 6.4-10.1 μL/min/cm(2) (0.8-1.3 mL/kg/min) for O2 and CO2 , respectively, were achieved. We also investigated protein adsorption to provide preliminary information on the need for application of anticoagulant coating of LAD materials. Albumin adsorption, as measured by gold staining, showed that surface uptake was evenly distributed and occurred at the monolayer level (>0.2 μg/cm(2) ). Finally, we also tested the LAD under in vivo conditions using a newborn piglet model (body weight 1.65-2.0 kg). First, the effect of an arteriovenous bypass via a carotid artery-to-jugular vein shortcut on heart rate and blood pressure was investigated. Heart rate and mean arterial blood pressure remained stable for extracorporeal flow rates of up to 61 mL/kg/min (101 mL/min). Next, the LAD was connected to umbilical vessels (maximum flow rate of 24 mL/min [10.4 mL/kg/min]), and O2 gas exchange was measured under hypoxic conditions (Fi O2 = 0.15) and was found to be 3.0 μL/min/cm(2) . These results are encouraging and support the feasibility of an artificial placental design for an LAD.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it