MétaCan
Menu
Back to cohort
Record W2106526441 · doi:10.1109/tbme.2015.2451517

Feasibility Study of Respiratory Motion Modeling Based Correction for MRI-Guided Intracardiac Interventional Procedures

2015· article· en· W2106526441 on OpenAlexafffund
Robert Xu, Prashant Athavale, Philippa Krahn, Kevan A. Anderson, Jennifer Barry, Labonny Biswas, Venkat Ramanan, Nicolas Yak, Mihaela Pop, Graham A. Wright

Bibliographic record

VenueIEEE Transactions on Biomedical Engineering · 2015
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsSunnybrook HospitalUniversity of TorontoSunnybrook Health Science Centre
FundersCanadian Institutes of Health ResearchGE Healthcare
KeywordsIntracardiac injectionMagnetic resonance imagingMotion compensationComputer scienceReal-time MRIComputer visionRespiratory monitoringMotion (physics)MedicineArtificial intelligenceRadiologyRespiratory systemSurgery

Abstract

fetched live from OpenAlex

GOAL: The purpose of this study is to improve the accuracy of interventional catheter guidance during intracardiac procedures. Specifically, the use of preprocedural magnetic resonance roadmap images for interventional guidance has limited anatomical accuracy due to intraprocedural respiratory motion of the heart. Therefore, we propose to build a novel respiratory motion model to compensate for this motion-induced error during magnetic resonance imaging (MRI)-guided procedures. METHODS: We acquire 2-D real-time free-breathing images to characterize the respiratory motion, and build a smooth motion model via registration of 3-D prior roadmap images to the real-time images within a novel principal axes frame of reference. The model is subsequently used to correct the interventional catheter positions with respect to the anatomy of the heart. RESULTS: We demonstrate that the proposed modeling framework can lead to smoother motion models, and potentially lead to more accurate motion estimates. Specifically, MRI-guided intracardiac ablations were performed in six preclinical animal experiments. Then, from retrospective analysis, the proposed motion modeling technique showed the potential to achieve a 27% improvement in ablation targeting accuracy. CONCLUSION: The feasibility of a respiratory motion model-based correction framework has been successfully demonstrated. SIGNIFICANCE: The improvement in ablation accuracy may lead to significant improvements in success rate and patient outcomes for MRI-guided intracardiac procedures.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.862
Threshold uncertainty score0.557

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.041
GPT teacher head0.320
Teacher spread0.279 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2015
Admission routes2
Has abstractyes

Explore more

Same venueIEEE Transactions on Biomedical EngineeringSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207