Bibliographic record
Abstract
Basically, there are two basic types of aortic valve-sparing operations: remodelling of the aortic root and reimplantation of the aortic valve [1]. After more than 2 decades of experience with these operations, we have concluded that they are not competitive procedures, but provide excellent long-term results when correctly matched to the aortic root pathology [2, 3]. Remodelling of the aortic root is physiologically superior to reimplantation of the aortic valve [4], but it does not address the problem of annular dilatation that often occurs in young patients with inherited aortic root aneurysms. As the dilatation of the aortic annulus can appear after the remodelling procedure, we believe that young patients are better served with reimplantation of the aortic valve. Remodelling of the aortic root is a good alternative to reimplantation of the aortic valve in older patients with normal aortic annulus and it is easier to perform. Regardless of the type of aortic valve sparing, restoration of normal aortic cusps geometry is the most important technical aspect of these operations. A key element for long-term success is the level and area of cusps coaptation. At the end of the procedure, the coaptation of the cusps must be inside the aortic root and a few millimetres above the level of the nadir of the aortic annulus, and the cusps coaptation length must be at least 4 mm. Remodelling of the aortic root has practically no adverse effect on systolic performance of the aortic valve because it does not change the diameter of the aortic annulus and has minimal effect on the movements of the aortic annulus during the cardiac cycle. In addition, the velocity of opening and closure of the cusps is only slightly increased [4]. Reimplantation of the aortic valve into a Dacron graft (straight tube or the Valsalva Graft by Vascutek Ltd, Renfreshsire, Scotland) alters every component of the aortic valve: the annulus, the cusps, the sinotubular junction and the aortic sinuses. The aortic annulus becomes rigid once sutured inside the Dacron graft. The degree of narrowing of the annulus will vary with the size of the graft used and the technique used for fixation of the annulus. The sinotubular junction is reduced and the aortic sinuses completely abolished when a straight tubular Dacron graft is used. The velocity of opening and closure of the aortic cusps is greatly increased in this operation [4], but it can be decreased by creating neo-aortic sinuses [5] or by using the Valsalva Graft [6]. Fixation of the aortic annulus and reduction of its diameter will invariably increase the impedance of blood flow to some degree that is not seen after remodelling of the aortic root. Actually, there is a case report of aortic stenosis after the reimplantation procedure because of purse stringing of the aortic annulus during its fixation in the tubular Dacron graft [7]. This is caused by a technical error that can be prevented by using grafts of adequate size and carefully tying the sub-annular sutures [2, 3]. In this issue of this journal, D’Ancona et al. [8] from Palermo, Italy, published a study that examined the haemodynamics of the aortic valve after the reimplantation technique in 17 patients and compared it with that of 18 matched controls. Aortic valve function was assessed by echocardiography at rest and during maximal exercise. Area of the left ventricular outflow tract and flow velocities were measured and the derivatives were calculated. Aortic valve area index at rest was 1.1 ± 0.2 cm/m in the reimplantation group and 1.5 ± 0.2 cm/m in the control group (P = 0.0001), and during maximal exercise it increased significantly to 1.4 ± 0.2 in the reimplantation group and to 1.7 ± 0.2 in the control group. There were no differences between the groups in peak and mean transvalvular gradients at rest and during exercise. Most patients in the reimplantation group had mild aortic insufficiency and the degree of valve dysfunction did not change during exercise. This is probably the first published study on systolic performance of the aortic valve after the reimplantation procedure into a straight Dacron tube in comparison with normal matched controls. Expectedly, the mean effective aortic valve orifice index after reimplantation of the aortic valve was smaller than that of matched controls, but the systolic performance was excellent and the aortic valve orifice increased in size during exercise. The size of the graft used for reimplantation certainly affects the aortic valve area. In D’Ancona’s study [8], the selection of the graft size was based on the diameter of the sinotubular junction, and grafts 26, 28 and 30 mm in diameter were used. The method used by these investigators to estimate the size of the graft is similar to our method, but we use grafts of >4–6 mm to create neo-aortic sinuses by placing darts in the graft in the spaces in between commissures where the valve is reimplanted [2, 3].
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.003 | 0.000 |
| Meta-epidemiology (narrow) | 0.001 | 0.001 |
| Meta-epidemiology (broad) | 0.002 | 0.004 |
| Bibliometrics | 0.001 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.002 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".