MétaCan
Menu
Back to cohort
Record W2108739466 · doi:10.1345/aph.1c105

Alteplase Versus Urokinase for Occluded Hemodialysis Catheters

2003· article· en· W2108739466 on OpenAlexaff
James Zacharias, Christine P Weatherston, Candace R Spewak, Lavern M. Vercaigne

Bibliographic record

VenueAnnals of Pharmacotherapy · 2003
Typearticle
Languageen
FieldHealth Professions
TopicCentral Venous Catheters and Hemodialysis
Canadian institutionsHealth Sciences CentreUniversity of Manitoba
Fundersnot available
KeywordsMedicineUrokinaseHemodialysisBlood flowHemodialysis CatheterTissue plasminogen activatorThrombosisAnesthesiaSurgeryCardiologyInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: The use of central venous catheters as a source of vascular access in patients undergoing hemodialysis may be complicated by thrombosis. Frequently, thrombolytics are used in an attempt to reestablish blood flow through partially or completely occluded catheters. OBJECTIVE: To compare the efficacy of alteplase (recombinant tissue plasminogen activator) versus urokinase in reestablishing adequate blood flow through partially or completely occluded vascular catheters. METHODS: Part 1 of the study prospectively investigated the effect of alteplase in reestablishing adequate blood flow through partially or completely occluded vascular catheters in 30 hemodialysis patients. Part 2 of the trial compared the efficacy of alteplase with that of urokinase in 14 of 30 patients who had also previously received urokinase. A 30-minute push-protocol was used to administer thrombolytics in both parts of the study. The primary endpoint was the proportion of patients with partially or completely occluded catheters achieving post-thrombolytic blood flow of > or =200 mL/min. RESULTS: Part 1 showed a large proportion of partially or completely occluded catheters achieving post-alteplase blood flows > or =200 mL/min (70/76, 92.1% vs. 34/40, 85%, respectively). In Part 2 of the study, the proportion of partially occluded catheters achieving post-thrombolytic blood flows > or =200 mL/min was not significantly different between the alteplase and urokinase groups, (36/41, 87.8% vs. 21/28, 75%, respectively; p = 0.205). The proportion of completely occluded catheters achieving post-thrombolytic blood flows > or =200 mL/min was significantly better with alteplase compared with urokinase (15/17, 88.2% vs. 6/14, 42.8%, respectively; p =.018). CONCLUSIONS: Alteplase, administered via the 30-minute push-protocol, is an effective thrombolytic for restoring hemodialysis catheter patency. In our study sample, alteplase was generally more effective than urokinase in restoring blood flow through catheters, especially those that were completely occluded.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.274
Threshold uncertainty score0.999

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.204
GPT teacher head0.488
Teacher spread0.284 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations52
Published2003
Admission routes1
Has abstractyes

Explore more

Same venueAnnals of PharmacotherapySame topicCentral Venous Catheters and HemodialysisFrench-language works237,207