Pulmonary Vein Isolation With Incomplete Antral Ablation Lines: Is More Ablation Necessary? Results of a Randomized Trial

2015· article· en· W2108905551 on OpenAlexafffund
Lorne J. Gula, Peter Leong‐Sit, Jaimie Manlucu, LINDSAY HILLOCK, Raymond Yee, Anthony Tang, George J. Klein, Allan C. Skanes

Bibliographic record

VenueJournal of Cardiovascular Electrophysiology · 2015
Typearticle
Languageen
FieldMedicine
TopicAtrial Fibrillation Management and Outcomes
Canadian institutionsWestern University
FundersLawson Health Research Institute
KeywordsMedicineAblationPulmonary veinLesionCatheter ablationVeinRandomized controlled trialSurgeryCardiologyRadiologyInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: A full circumferential set of antral lesions is not always required for bidirectional pulmonary vein conduction block. It is unknown whether a partial lesion set that isolates the veins will have clinical success rates similar to a full circumferential lesion set, and if procedural times or procedural risk will be affected. METHODS: We performed a prospective, randomized clinical trial to test the hypothesis that a partial lesion set that isolates the pulmonary veins has comparable clinical success rate and shorter procedure times compared to a strategy of completing the circumferential lesion set once the veins are isolated. RESULTS: A total of 119 patients were enrolled, 59 randomized to circumferential ablation, and 60 to segmental. Mean age was 58.3 ± 10.1, 77% male. Mean procedure time was 221.0 ± 46.9 minutes in circumferential and 224.7 ± 51.3 in segmental (P = 0.68). Twelve-month freedom from AF recurrence was 61.3% overall, 64.4% in circumferential, and 58.3% in segmental (P = 0.50). Among 25 segmental patients with AF recurrence, 23 underwent second ablation. Among 33 areas of conduction recovery, 23 (70%) occurred in segments ablated at first procedure and 10 (30%) in segments not previously ablated, suggesting reversible conduction block from edema. CONCLUSION: No difference in AF recurrence or procedure time is detectable in a sample of 119 patients randomized to segmental or circumferential antral ablation to achieve pulmonary vein isolation. Second ablation procedures confirmed that some antral sites do not require ablation. A segmental approach results in unacceptably high rates of untargeted or recovered antral sites to make this approach feasible.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.012
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.007
Threshold uncertainty score0.033

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0060.012
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0040.003
Bibliometrics0.0000.001
Science and technology studies0.0000.001
Scholarly communication0.0020.002
Open science0.0010.000
Research integrity0.0030.003
Insufficient payload (model declined to judge)0.0070.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.032
GPT teacher head0.293
Teacher spread0.260 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2015
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Cardiovascular ElectrophysiologySame topicAtrial Fibrillation Management and OutcomesFrench-language works237,207