MétaCan
Menu
Back to cohort

Effect of Home Blood Pressure Telemonitoring With Self-Care Support on Uncontrolled Systolic Hypertension in Diabetics

2012· article· en· W2109296948 on OpenAlexaff
Alexander G. Logan, M. Jane Irvine, Warren J. McIsaac, András Tislér, Peter G. Rossos, Anthony Easty, Denice S. Feig, Joseph A Cafazzo

Bibliographic record

VenueHypertension · 2012
Typearticle
Languageen
FieldMedicine
TopicBlood Pressure and Hypertension Studies
Canadian institutionsYork UniversityUniversity of TorontoUniversity Health NetworkMount Sinai Hospital
Fundersnot available
KeywordsMedicineBlood pressureAmbulatory blood pressureDepression (economics)AnxietyInternal medicineRandomized controlled trialDiabetes mellitusAmbulatoryPhysical therapyCardiologyEndocrinology

Abstract

fetched live from OpenAlex

Lowering blood pressure reduces cardiovascular risk, yet hypertension is poorly controlled in diabetic patients. In a pilot study we demonstrated that a home blood pressure telemonitoring system, which provided self-care messages on the smartphone of hypertensive diabetic patients immediately after each reading, improved blood pressure control. Messages were based on care paths defined by running averages of transmitted readings. The present study tests the system's effectiveness in a randomized, controlled trial in diabetic patients with uncontrolled systolic hypertension. Of 244 subjects screened for eligibility, 110 (45%) were randomly allocated to the intervention (n = 55) or control (n = 55) group, and 105 (95.5%) completed the 1-year outcome visit. In the intention-to-treat analysis, mean daytime ambulatory systolic blood pressure, the primary end point, decreased significantly only in the intervention group by 9.1 ± 15.6 mmHg (SD; P < 0.0001), and the mean between-group difference was 7.1 ± 2.3 mmHg (SE; P < 0.005). Furthermore, 51% of intervention subjects achieved the guideline recommended target of <130/80 mmHg compared with 31% of control subjects (P < 0.05). These improvements were obtained without the use of more or different antihypertensive medications or additional clinic visits to physicians. Providing self-care support did not affect anxiety but worsened depression on the Hospital Anxiety and Depression Scale (baseline, 4.1 ± 3.76; exit, 5.2 ± 4.30; P = 0.014). This study demonstrated that home blood pressure telemonitoring combined with automated self-care support reduced the blood pressure of diabetic patients with uncontrolled systolic hypertension and improved hypertension control. Home blood pressure monitoring alone had no effect on blood pressure. Promoting patient self-care may have negative psychological effects.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Non-randomized trial · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.235
Teacher spread0.224 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNon-randomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations222
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueHypertensionSame topicBlood Pressure and Hypertension StudiesFrench-language works237,207