MétaCan
Menu
Back to cohort
Record W2110190544 · doi:10.1111/cid.12061

Mechanical Property Assessment of Bone Healing around a Titanium–Zirconium Alloy Dental Implant

2013· article· en· W2110190544 on OpenAlexvenueno aff
Rodolfo Bruniera Anchieta, Marta Baldassarri, Fernando Pozzi Semeghini Guastaldi, Nick Tovar, Malvin N. Janal, Jan Gottlow, Michel Dard, Ryo Jimbo, Paulo G. Coelho

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2013
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsNanoindentationMaterials scienceTitaniumElastic modulusZirconiumDental implantOsseointegrationTitanium alloyDentistryImplantPremolarAlloyMolarComposite materialMedicineMetallurgySurgery

Abstract

fetched live from OpenAlex

BACKGROUND: It has been reported that titanium-zirconium alloy with 13-17% zirconium (TiZr1317) implants show higher biomechanical stability and bone area percentage relative to commercially pure titanium (cpTi) grade 4 fixtures. PURPOSE: This study aimed to determine whether the higher stability for TiZr1317 implants is associated with higher mechanical properties of remodeling bone in the areas around the implants. MATERIALS AND METHODS: This study utilized 36 implants (n = 18: TiZr1317, n = 18: cpTi), which were placed in the healed ridges of the mandibular premolar and first molar of 12 mini pigs (n = 3 implants/animal). After 4 weeks in vivo, the samples were retrieved, and resin-embedded histologic sections of approximately 100 μm in thickness were prepared. In order to determine the nanomechanical properties, nanoindentation (n = 30 tests/specimen) was performed on the bone tissue of the sections under wet conditions with maximum load of 300 μN (loading rate: 60 μN/s). RESULTS: The mean (± standard deviation) elastic modulus (E) and hardness (H) for the TiZr1317 group were 2.73 ± 0.50 GPa and 0.116 ± 0.017 GPa, respectively. For the cpTi group, values were 2.68 ± 0.51 GPa and 0.110 ± 0.017 GPa for E and H, respectively. Although slightly higher mechanical properties values were observed for the TiZr1317 implants relative to the cpTi for both elastic modulus and hardness, these differences were not significant (E = p > 0.75; H = p > 0.59). CONCLUSIONS: The titanium-zirconium alloy used in this study presented similar degrees of nanomechanical properties to that of the cpTi implants.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.123
GPT teacher head0.465
Teacher spread0.342 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations39
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related ResearchSame topicDental Implant Techniques and OutcomesFrench-language works237,207