MétaCan
Menu
Back to cohort
Record W2111677857 · doi:10.1016/j.hrthm.2014.05.015

A novel algorithm to assess risk of heart failure exacerbation using ICD diagnostics: Validation from RAFT

2014· article· en· W2111677857 on OpenAlexaff
Lorne J. Gula, George A. Wells, Raymond Yee, Jodi Koehler, Shantanu Sarkar, Vinod Sharma, Allan C. Skanes, John L. Sapp, Damian Redfearn, Jaimie Manlucu, Anthony Tang

Bibliographic record

VenueHeart Rhythm · 2014
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsQueen's UniversityQueen Elizabeth II Health Sciences CentreUniversity of OttawaWestern University
FundersSt. Jude MedicalMedtronic
KeywordsMedicineHeart failureImplantable cardioverter-defibrillatorCardiac resynchronization therapyInternal medicineAmbulatoryCardiologyExacerbationConfidence intervalDefibrillationHeart rateAlgorithmEjection fractionBlood pressure

Abstract

fetched live from OpenAlex

BackgroundThe integrated diagnostics (ID) algorithm is an implantable device-based tool that collates data pertaining to heart rhythm, heart rate, intrathoracic fluid status, and activity, producing a risk score that correlates with 30-day risk of heart failure (HF) hospitalization.ObjectiveWe sought to validate the ID algorithm using the Resynchronization-Defibrillation for Ambulatory Heart Failure Trial.MethodsDiagnostic measures of the algorithm include OptiVol fluid index, nighttime heart rate, minutes of patient activity, heart rate variability, and combined measure of cardiac rhythm and biventricular pacing. Monthly evaluations of ID parameters were assessed for the development of HF symptoms and hospitalization for HF.ResultsA total of 1224 patients were included: 741 (61%) with cardiac resynchronization therapy with defibrillator devices and 483 (39%) with implanted cardioverter-defibrillator only. The mean age was 66 ± 9 years, and 1013 (83%) were men. A total of 37,861 months of follow-up data were available, with 258 HF hospitalizations (event rate 0.68% per month). There were 33 HF hospitalizations during low-risk months (0.21% per month), 123 during medium-risk months (0.66% per month), and 102 during high-risk months (2.61% per month). Compared with low-risk months, and 95% confidence intervals) of HF hospitalizations during medium-risk months was 2.9 (2.0–4.4) and during high-risk months was 10.7 (6.9–16.6). Multivariable analysis demonstrated that each ID variable had independent association with HF hospitalization.ConclusionThe risk of HF as determined by the ID algorithm correlated with HF hospitalization and several HF signs and symptoms among patients in the Resynchronization-Defibrillation for Ambulatory Heart Failure Trial. This may present a useful adjunct to detect early signs of HF and adjust therapy to reduce morbidity and costs involved with hospital admission. The integrated diagnostics (ID) algorithm is an implantable device-based tool that collates data pertaining to heart rhythm, heart rate, intrathoracic fluid status, and activity, producing a risk score that correlates with 30-day risk of heart failure (HF) hospitalization. We sought to validate the ID algorithm using the Resynchronization-Defibrillation for Ambulatory Heart Failure Trial. Diagnostic measures of the algorithm include OptiVol fluid index, nighttime heart rate, minutes of patient activity, heart rate variability, and combined measure of cardiac rhythm and biventricular pacing. Monthly evaluations of ID parameters were assessed for the development of HF symptoms and hospitalization for HF. A total of 1224 patients were included: 741 (61%) with cardiac resynchronization therapy with defibrillator devices and 483 (39%) with implanted cardioverter-defibrillator only. The mean age was 66 ± 9 years, and 1013 (83%) were men. A total of 37,861 months of follow-up data were available, with 258 HF hospitalizations (event rate 0.68% per month). There were 33 HF hospitalizations during low-risk months (0.21% per month), 123 during medium-risk months (0.66% per month), and 102 during high-risk months (2.61% per month). Compared with low-risk months, and 95% confidence intervals) of HF hospitalizations during medium-risk months was 2.9 (2.0–4.4) and during high-risk months was 10.7 (6.9–16.6). Multivariable analysis demonstrated that each ID variable had independent association with HF hospitalization. The risk of HF as determined by the ID algorithm correlated with HF hospitalization and several HF signs and symptoms among patients in the Resynchronization-Defibrillation for Ambulatory Heart Failure Trial. This may present a useful adjunct to detect early signs of HF and adjust therapy to reduce morbidity and costs involved with hospital admission.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.215
Threshold uncertainty score0.573

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.039
GPT teacher head0.313
Teacher spread0.275 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations33
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueHeart RhythmSame topicCardiac pacing and defibrillation studiesFrench-language works237,207