MétaCan
Menu
Back to cohort
Record W2114266070 · doi:10.1111/jsm.12009

Comparison Between AMS 700™ CX and Coloplast™ Titan Inflatable Penile Prosthesis for Peyronie's Disease Treatment and Remodeling: Clinical Outcomes and Patient Satisfaction

2012· article· en· W2114266070 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueThe Journal of Sexual Medicine · 2012
Typearticle
Languageen
FieldMedicine
TopicSexual function and dysfunction studies
Canadian institutionsSt Joseph's Health Care
Fundersnot available
KeywordsPeyronie's diseasePenile prosthesisMedicineErectile dysfunctionPatient satisfactionUrologySurgery

Abstract

fetched live from OpenAlex

INTRODUCTION: The implantation of inflatable penile prosthesis (IPP) with simultaneous manual penile remodeling allows for men to undergo a single procedure aimed at correcting both the penile deformity/curvature and erectile dysfunction (ED). AIM: To evaluate the clinical outcomes and patient satisfaction in men with Peyronie's disease (PD) and ED who underwent AMS 700™ CX and the newer Coloplast™ Titan inflatable penile prosthesis (IPP) implant. MAIN OUTCOME MEASURES: Patient demographics, type of IPP, clinical outcomes, post-implant sexual characteristics, and overall patient satisfaction. METHODS: A single-center retrospective review of clinical database and prospective telephone survey were conducted in all men with PD who underwent IPP between January 2006 and November 2010. RESULTS: A total of 138 patients with an average age of 57.7 (32 to 80) underwent AMS 700 CX (88 patients) and Coloplast Titans (50 patients) IPP implantation during the 5-year period. The majority of patients (91%) had only one IPP implantation. The IPP clinical outcomes include eight (6%) revision surgery for device malfunction and three (2%) device explantation for prosthesis infection. While there was no statistically significance in device survival between the two devices, the trend favored AMS 700 CX over Titan (5-year Kaplan-Meier estimates of mechanical survival were 91% vs. 87%, P>0.05) and both IPPs provided similar penile straightening without the need for revision surgery. Most men (79%) reported great satisfaction following CX or Titan implants with greater than two thirds of men reported greater self-confidence and 82% of patients would undergo the same operation again. CONCLUSIONS: AMS 700™ CX and Coloplast™ Titan IPP implantation and penile remodeling appeared to provide permanent penile straightening and high patient satisfaction without an increase risk of revision surgery.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.055
Threshold uncertainty score0.350

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.141
GPT teacher head0.411
Teacher spread0.269 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it