MétaCan
Menu
Back to cohort
Record W2114461326 · doi:10.1117/12.844253

An MRI-compatible three-axis focused ultrasound system for performing drug delivery studies in small animal models

2010· article· en· W2114461326 on OpenAlexafffund
Adam C. Waspe, Anthony Chau, Aleksandra Kukic, Rajiv Chopra, Kullervo Hynynen

Bibliographic record

VenueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2010
Typearticle
Languageen
FieldEngineering
TopicUltrasound and Hyperthermia Applications
Canadian institutionsUniversity of TorontoSunnybrook Health Science Centre
FundersCanada Research ChairsNational Institute for Health and Care ResearchNational Institutes of HealthAgilent Technologies
KeywordsImaging phantomComputer scienceRadiofrequency coilTransducerElectromagnetic coilAcousticsPositioning systemEncoderActuatorUltrasoundRotary encoderInterventional magnetic resonance imagingBiomedical engineeringMaterials scienceMagnetic resonance imagingOpticsArtificial intelligencePhysicsRadiologyEngineering

Abstract

fetched live from OpenAlex

MRI-guided focused-ultrasound is a non-invasive technique that can enhance the delivery of therapeutic agents. The objective of this work was to develop a focused-ultrasound system for preclinical research in small animals that is capable of sonicating with high spatial precision within a closed-bore MRI. The system features a computer-controlled, non-magnetic, three-axis positioning system that uses piezoelectric actuators and linear optical encoders to position a focused-ultrasound transducer to targeted tissues under MRI guidance. The actuator and encoder signals are transmitted through low-pass-filtered connectors on a grounded RF-penetration panel to prevent artifacts during image acquisition. The transducer is attached to the positioning system by a rigid arm and is submerged within a closed water tank. The arm passes into the tank through flexible bellows to ensure that the system remains sealed. An RF coil acquires high-resolution images in the vicinity of the target tissue. An aperture on the water tank, centered about the RF coil, provides an access point for target sonication. Registration between ultrasound and MRI coordinates involves sonicating a temperature-sensitive phantom and measuring the centroid of the thermal focal zone in 3D with MR thermometry. Linear distances of 5 cm with a positioning resolution of 0.05 mm can be achieved for each axis. The system was operated successfully on MRI scanners from different vendors at both 1.5 and 3.0 T, and simultaneous motion and imaging was possible without any mutual interference or imaging artifacts. This system is used for high-throughput small-animal experiments to study the efficacy of ultrasound-enhanced drug delivery.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.005
Threshold uncertainty score0.015

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0010.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0050.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.235
Teacher spread0.214 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2010
Admission routes2
Has abstractyes

Explore more

Same venueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIESame topicUltrasound and Hyperthermia ApplicationsFrench-language works237,207