MétaCan
Menu
Back to cohort
Record W2116095238 · doi:10.1039/c004857g

Microfluidic perfusion system for culturing and imaging yeast cell microarrays and rapidly exchanging media

2010· article· en· W2116095238 on OpenAlexafffund
Maryam Mirzaei, Mateu Pla‐Roca, Roozbeh Safavieh, Elena Nazarova, Mohammadali Safavieh, Huiyan Li, Jackie Vogel, David Juncker

Bibliographic record

VenueLab on a Chip · 2010
Typearticle
Languageen
FieldEngineering
TopicMicrofluidic and Bio-sensing Technologies
Canadian institutionsMcGill University and Génome Québec Innovation CentreMcGill University
FundersCanadian Institutes of Health Research
KeywordsMicrofluidicsPipetteLive cell imagingFluorescence microscopeMicrofabricationMicroscopyMembraneNanotechnologyYeastBiomedical engineeringMaterials scienceChemistryBiophysicsFluorescenceCellBiologyBiochemistryFabrication

Abstract

fetched live from OpenAlex

High resolution live cell microscopy is increasingly used to detect cellular dynamics in response to drugs and chemicals, but it depends on complex and expensive liquid handling devices that have limited its wider adoption. Here, we present a microfluidic perfusion system that is built without using specialized microfabrication infrastructure, simple to use because only a pipette is needed for liquid handling, and yet allows for rapid media exchange and simultaneous fluorescence microscopy imaging. Yeast cells may be introduced from a culture, or spotted as arrays on a coverslip, and are sandwiched with a 20 mum thick track-etched membrane. A second coverslip and a mesh with 120 mum porosity are placed on top, forming a microfluidic conduit for lateral flow of solutions by capillary effects. Solutions introduced through the inlet flow through the mesh and chemicals diffuse vertically across the membrane to the cells trapped below. Solutions are exchanged by adding a new sample to the inlet. Using this system, we studied the dynamic response of F-actin in living yeast expressing Sac6-EGFP-a protein associated with discrete F-actin structures called "patches"-to the drug latrunculin A, a well known inhibitor of actin polymerization. We observed that the patches disappeared in 85% of the cells within 5 min, and re-assembled in 45 min following exchange of the drug with media. The perfusion system presented here is a simple, inexpensive device suited for analysis of drug dose-response and regeneration of single cells and arrays of cells.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.011
Threshold uncertainty score0.719

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.179
Teacher spread0.174 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations18
Published2010
Admission routes2
Has abstractyes

Explore more

Same venueLab on a ChipSame topicMicrofluidic and Bio-sensing TechnologiesFrench-language works237,207