Quantifying degree of difficulty in hip - resurfacing of pistol-grip deformity.
Bibliographic record
Abstract
This study used computer simulation to endeavor to quantify the relative degree of difficulty of resurfacing femora with pistol-grip deformities compared to relatively normal femora. Computer models of five pistol-grip femora and one relatively normal femur were computed from computed tomography (CT) scans of patients who had undergone computer-assisted hip resurfacing. A computer simulation of positioning the femoral resurfacing component on the femur was performed to count the number of acceptable configurations of the component on the femur. A high number of acceptable configurations implies that the surgeon has greater freedom, or greater margin for error, in implanting the component compared to a femur with a smaller number of acceptable configurations. We found that pistol-grip deformities dramatically reduce the number of acceptable configurations for valgus alignment, and that such configurations result in decreased femoral offset and increased depth of reaming.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.007 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.001 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.002 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".