MétaCan
Menu
Back to cohort

Potential Use of Therapeutic Ultrasound in Ischemic Stroke Treatment

2001· review· en· W2116772419 on OpenAlexaboutno aff
Stephan Behrens, Konstantinos Spengos, Michael Daffertshofer, Steffen Wirth, Michael G. Hennerici

Bibliographic record

VenueEchocardiography · 2001
Typereview
Languageen
FieldEngineering
TopicUltrasound and Hyperthermia Applications
Canadian institutionsnot available
Fundersnot available
KeywordsThrombolysisMedicineUltrasoundTranscranial DopplerTherapeutic ultrasoundStroke (engine)RadiologyCardiologyMyocardial infarction

Abstract

fetched live from OpenAlex

Systemic treatment with rtPA approved for a 3-hour window is the only established causal therapy for acute stroke in the United States and Canada. Thrombolytic therapy with rtPA demonstrated a small, although significantly reduced morbidity, in a limited number of highly selected patients. As recently shown, intraarterial application is favorable and opens the window of treatment up to 6 hours. The combination of ultrasound with thrombolytic agents may further enhance the potential benefit by means of enzymatic-mediated thrombolysis, which has been demonstrated in different in vitro and in vivo experiments for an accelerated recanalization of occluded peripheral and coronary vessels. Whereas no or only small attenuation of ultrasound can be expected through skin and chest, intensity will be significantly attenuated if penetration of the skull is required. The transcranial penetration of ultrasound increases when the frequency is decreased to 20 kHz and may be transmitted through the skull transtemporally with tolerable attenuation up to 200 kHz. This results in efficacy in vitro with low intensities of 0.5-2.0 W/cm(2) systemic treatment with rtPA approved for a 3-hour window in the nonfocused ultrasound field. Application of ultrasound insonation increased rtPA-mediated thrombolysis up to 20% in a static model; meanwhile, it enhanced the recanalization rate from 30%-90% in a flow model. In vitro results suggest that 1 MHz ultrasound with 0.5 W/cm(2), established for diagnostic purposes, may already enhance rtPA- mediated thrombolysis. Before therapeutic ultrasound can be tested clinically in acute stroke, safety of transcranial exposure of the brain has to be confirmed. To date, animal experiments suggested no harm to the blood brain barrier or systemic heating with 2 W/cm(2). This combined treatment is one perspective in optimizing therapy in acute stroke within the acute phase and may be applied easily with few limitations.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.005
Threshold uncertainty score0.017

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0050.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.031
GPT teacher head0.259
Teacher spread0.229 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations30
Published2001
Admission routes1
Has abstractyes

Explore more

Same venueEchocardiographySame topicUltrasound and Hyperthermia ApplicationsFrench-language works237,207