MétaCan
Menu
Back to cohort
Record W2117379853 · doi:10.5539/jsd.v4n1p230

Effect of Short Steel Fibre Reinforcement on Laterized Concrete Columns

2011· article· en· W2117379853 on OpenAlexvenueno aff
Efe Ikponmwosa, Musbau Ajibade Salau

Bibliographic record

VenueJournal of Sustainable Development · 2011
Typearticle
Languageen
FieldEngineering
TopicStructural Behavior of Reinforced Concrete
Canadian institutionsnot available
Fundersnot available
KeywordsMaterials scienceComposite materialReinforcementCementReinforced concreteVolume (thermodynamics)Shear (geology)Structural engineering

Abstract

fetched live from OpenAlex

This paper reports on experimental investigation conducted to determine the effect of short randomly oriented and discontinuous steel fibres on the structural behaviour of laterized concrete columns. Thirty fibre reinforced concrete columns of 150 x 150mm cross-sectional area and 1200mm in height and sixty number 150 x 150 x 150mm cubes were cast and tested. Fifteen fibre reinforced concrete columns were provided with 8mm mild steel links at 300mm spacing while the remaining fifteen (15) specimens of the fibre reinforced concrete columns were not provided with links except at the top and bottom of the bars to hold the longitudinal reinforcements in position. The mix proportion for this investigation is 2:3:6 (cement: Laterite/sand: Granite) with 0.65 water/cement ratio. The specimens were cured in water at different ages up to 28 days at temperature of 21o ± 1oC. The steel fibre was varied from 0% to 2% at 0.5% interval.The first crack load and ultimate column strength increases with increasing fibre proportion up to an optimum fibre content of 1.5% of the volume of laterized concrete. There is approximately linear relationship between the ultimate strength and the percentage of fibres in the laterized concrete up to this optimum level. Results also indicate that an addition of 1% fibre by volume of concrete can be an effective replacement for 8mm non-shear links in laterized concrete columns. It was observed that there was no appreciable effect of additional steel links on loading when fibres are present in the mix, showing that fibre reinforced laterized concrete short columns may be used without additional steel links in provision of minor structures, as well as low rise buildings, where nominal shear reinforcement is needed.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.330
Threshold uncertainty score0.931

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.218
Teacher spread0.208 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Sustainable DevelopmentSame topicStructural Behavior of Reinforced ConcreteFrench-language works237,207