MétaCan
Menu
Back to cohort

A comparison of dose warping methods for 4D Monte Carlo dose calculations in lung

2008· article· en· W2118086214 on OpenAlexafffund
Emily Heath, Joao Seco, Zhong Wu, G Sharp, Harald Paganetti, Jan Seuntjens

Bibliographic record

VenueJournal of Physics Conference Series · 2008
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsMcGill University
FundersNational Cancer InstituteNational Institutes of HealthTerry Fox Foundation
KeywordsMonte Carlo methodNuclear medicineImage warpingInterpolation (computer graphics)MathematicsComputer scienceMedicineStatisticsMotion (physics)Artificial intelligence

Abstract

fetched live from OpenAlex

Dose calculation methods which incorporate tissue motion are an important tool for evaluating the effect of respiratory motion on the delivered dose distribution. 4D dose calculation methods use a sum of remapped doses calculated on 4D CT images of the patient at different respiratory phases to determine the cumulative dose received over the entire respiratory cycle. A number of methods for remapping the dose to the reference phase have been proposed, including center-of-mass (COM) tracking and trilinear (TL) interpolation. In this work we compare calculations of dose distributions remapped between extreme breathing phases against a 4D Monte Carlo dose code defDOSXYZ for three planning scenarios. No clinically significant differences were noted between dose distributions calculated by the three methods with the exception of an extreme motion evaluation case where TL and COM remapping underestimated the 95% target dose coverage by up to 16%. The accuracy of these dose calculation methods is significantly affected by the continuity of the deformation fields from non-linear image registration.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.005
metaresearch head score (Gemma)0.017
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.005
Threshold uncertainty score0.024

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0050.017
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.002
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.066
GPT teacher head0.424
Teacher spread0.358 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2008
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Physics Conference SeriesSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207