MétaCan
Menu
Back to cohort
Record W2121512644 · doi:10.1371/journal.pone.0011040

Drug-Eluting versus Bare-Metal Stent for Treatment of Saphenous Vein Grafts: A Meta-Analysis

2010· review· en· W2121512644 on OpenAlexfundno aff
Pascal Meier, Emmanouil S. Brilakis, Roberto Corti, Guido Knapp, Mehdi H. Shishehbor, Hitinder S. Gurm

Bibliographic record

VenuePLoS ONE · 2010
Typereview
Languageen
FieldMedicine
TopicCoronary Interventions and Diagnostics
Canadian institutionsnot available
FundersAbbott VascularMedicureWake Forest University
KeywordsMedicineRandomized controlled trialInternal medicineOdds ratioClinical endpointStentMyocardial infarctionRevascularizationObservational studyCardiologySurgeryMeta-analysis

Abstract

fetched live from OpenAlex

BACKGROUND: Saphenous vein grafts develop an aggressive atherosclerotic process and the efficacy of drug eluting stents (DES) in treating saphenous vein graft (SVG) lesions has not been convincingly demonstrated. The aim of this study was to review and analyze the current literature for controlled studies comparing DES versus bare metal stents (BMS) for treatment of SVG stenoses. METHODOLOGY/PRINCIPAL FINDINGS: We searched several scientific databases and conference proceedings up to March 15, 2010 for controlled studies comparing target vessel revascularization (TVR) between DES and BMS. Summary odds ratios (OR) for the primary endpoint TVR and secondary endpoints infarction, stent thrombosis and death were calculated using random-effect models. A total of 29 studies (3 randomized controlled trials RCT) involving 7549 (202 in RCT) patients were included. The need for target vessel revascularization in the DES group tended to be lower compared to BMS for the 3 RCT (OR 0.50 [0.24-1.00]; p = 0.051) and for observational studies (0.62 [0.49-0.79]; p<0.001). There was no significant difference in the risk for myocardial infarction in the RCT (OR 1.25 [0.22-6.99]; p = 0.250) but a lower risk for DES based on the observational studies 0.68 [0.49-0.95]; p = 0.023. The risk for stent thrombosis was found to be non-different in the RCT (OR 0.78 [0.03-21.73], p = 0.885) while it was in favor of DES in the observational studies (0.58 [0.38 - 0.84]; p<0.001). The mortality was not significantly different between DES and BMS in the RCT's (OR 2.22 [0.17 - 29.50]; p = 0.546) while the observation studies showed a decreased mortality in the DES group (0.69 [0.55-0.85]; p<0.001). CONCLUSION: DES may decrease TVR rate in treatment of SVG stenoses. No differences in reinfarction rate, stent thrombosis or mortality was found between the DES and BMS groups in the RCT's while the observational data showed lower risk for myocardial infarction, stent thrombosis and death in the DES group. This may be a result of patient selection bias in the observational studies or represent a true finding that was not the detected in the RCT analysis due to limited statistical power.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.012
metaresearch head score (Gemma)0.021
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: Meta-analysis
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.015
Threshold uncertainty score0.065

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0120.021
Meta-epidemiology (narrow)0.0030.001
Meta-epidemiology (broad)0.0150.041
Bibliometrics0.0040.004
Science and technology studies0.0010.001
Scholarly communication0.0030.001
Open science0.0020.001
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.351
GPT teacher head0.381
Teacher spread0.031 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designMeta-analysis
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations55
Published2010
Admission routes1
Has abstractyes

Explore more

Same venuePLoS ONESame topicCoronary Interventions and DiagnosticsFrench-language works237,207