MétaCan
Menu
Back to cohort
Record W2121756777

Dimensional accuracy of 2 irreversible hydrocolloid alternative impression materials with immediate and delayed pouring.

2012· article· en· W2121756777 on OpenAlexaff
Usama Nassar, Bayan Hussein, Andrea Oko, Jason P. Carey, Carlos Flores‐Mir

Bibliographic record

VenuePubMed · 2012
Typearticle
Languageen
FieldDentistry
TopicDental materials and restorations
Canadian institutionsUniversity of Alberta
Fundersnot available
KeywordsImpressionDentistryRepeated measures designOrthodonticsMaterials scienceComputer scienceBiomedical engineeringMathematicsMedicineStatistics
DOInot available

Abstract

fetched live from OpenAlex

OBJECTIVE: To assess dimensional accuracy and stability of 2 irreversible hydrocolloid alternative impression materials with immediate and delayed pouring. METHODS: Two alternative impression materials, AlgiNot FS and Position Penta Quick, were compared with a traditional irreversible hydrocolloid, Jeltrate Plus antimicrobial alginate. Impressions were made of a metal model with 4 cylinders of known dimensions, with pouring performed immediately or after 4 hours of storage. A digital micrometer was used to measure cylinder diameter on the model and the poured casts. Dimensional changes were analyzed according to American National Standards Institute/American Dental Association (ANSI/ADA) Specification 19 (2004 version) (α=0.05). RESULTS: There were significant differences among the 3 materials, between the 2 pour times and as a function of storage time (multivariate analysis of variance, p<0.001). One-way analysis of variance revealed no significant differences between the 2 alternative impression materials, but changes for these materials differed significantly from those for the traditional impression material for immediate (p<0.05) and 4-hour (p<0.001) pouring. Linear dimensional changes for the 2 substitute materials were within the limits of the ANSI/ADA specification. CONCLUSIONS: With immediate pouring, both alternative impression materials exhibited minimal dimensional changes, which were maintained or reduced with 4-hour pouring. For both pouring times, these changes were less than 0.5%. CLINICAL SIGNIFICANCE: The minimal dimensional changes observed with these irreversible hydrocolloid alternative impression materials after 4 hours of storage may save chairside time and help to produce accurate results for procedures such as partial denture framework, surgical guides, and pediatric and orthodontic devices.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.008
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.014

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.008
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.239
Teacher spread0.223 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations20
Published2012
Admission routes1
Has abstractyes

Explore more

Same venuePubMedSame topicDental materials and restorationsFrench-language works237,207