MétaCan
Menu
← all works

Comparative Analysis Between ROCOF and Vector Surge Relays for Distributed Generation Applications

2005· article· en· 372 citations· W2124393453 on OpenAlex· 10.1109/tpwrd.2004.834869

Why is this work in the frame?

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

Canadian affiliationAn author listed a Canadian institution. This is the only route the usual frame has.

Full frame distilled prediction

Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

Candidate categories
none
Consensus categories
none
Domain
Candidate signal: noneConsensus signal: none
Study design
Candidate signal: Simulation or modelingConsensus signal: Simulation or modeling
Genre
Candidate signal: EmpiricalConsensus signal: none
Teacher disagreement score
0.923
Threshold uncertainty score
0.852
Validation status
machine_predicted_unvalidated · codex-gemma-dda1882f352a

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Opus teacher head0.022
GPT teacher head0.244
Teacher spread
0.223 · how far apart the two teachers sit on this one work
Validation status
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Abstract

This paper presents a comprehensive comparative analysis between rate-of-change-of-frequency (ROCOF) and vector-surge (VS) relays for distributed generation islanding detection. The analysis is based on the concepts of detection-time versus active power-imbalance curves and critical active power imbalance. Such curves are obtained through dynamic simulations. The performance of these devices considering different scenarios is determined and compared. Factors such as voltage-dependent loads, generator inertia constant, and multidistributed generator systems are analyzed. False operation of these relays due to faults in adjacent feeders is also addressed. Results show that ROCOF relays are more reliable to detect islanding than vector surge relays when the active power imbalance in the islanded system is small. However, ROCOF relays are more susceptible to false operation than VS relays.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

The record

Venue
IEEE Transactions on Power Delivery
Topic
Islanding Detection in Power Systems
Field
Engineering
Canadian institutions
University of Alberta
Funders
not available
Keywords
IslandingElectric power systemSurgeGenerator (circuit theory)Control theory (sociology)Protective relayEngineeringAC powerPower (physics)RelayComputer scienceDistributed generationVoltageReliability engineeringElectronic engineeringElectrical engineeringRenewable energy
Has abstract in OpenAlex
yes