Total body water and ECFV measured using bioelectrical impedance analysis and indicator dilution in horses
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
The purposes of this study were 1) to determine the compartmentation of body water in horses by using indicator dilution techniques and 2) to simultaneously measure bioelectrical impedance to current flow at impulse current frequencies of 5 and 200 kHz to formulate predictive equations that could be used to estimate total body water (TBW), extracellular fluid volume (ECFV), and intracellular fluid volume (ICFV). Eight horses and ponies weighing from 214 to 636 kg had catheters placed into the left and right jugular veins. Deuterium oxide, sodium thiocyanate, and Evans blue were infused for the measurement of TBW, ECFV, and plasma volume (PV), respectively. Bioelectrical impedance was measured by using a tetrapolar electrode configuration, with electrode pairs secured above the knee and hock. Measured TBW, ECFV, and PV were 0.677 +/- 0.022, 0.253 +/- 0.006, and 0.040 +/- 0.002 l/kg body mass, respectively. Strong linear correlations were determined among measured variables that allowed for the prediction of TBW, ECFV, ICFV, and PV from measures of horse length or height and impedance. It is concluded that bioelectrical impedance analysis (BIA) can be used to improve the predictive accuracy of noninvasive estimates of ECFV and PV in euhydrated horses at rest.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it