MétaCan
Menu
Back to cohort
Record W2126157805 · doi:10.9778/cmajo.20130005

Comparison of blood pressure measurements using an automated blood pressure device in community pharmacies and family physicians' offices: a randomized controlled trial

2013· article· en· W2126157805 on OpenAlexafffundvenueabout
Larry W. Chambers, Janusz Kaczorowski, Siobhán O'Rielly, Sandra Ignagni, Stephen Hearps

Bibliographic record

VenueCMAJ Open · 2013
Typearticle
Languageen
FieldMedicine
TopicBlood Pressure and Hypertension Studies
Canadian institutionsUniversity of British ColumbiaOntario Centre of Excellence for Child and Youth Mental HealthUniversité de MontréalBruyère
FundersBruyère Research InstituteCanadian Stroke Network
KeywordsBlood pressurePharmacyMedicineRandomized controlled trialCommunity pharmacyFamily medicineEmergency medicineMedical physicsInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: Accurate measurement of blood pressure is the foundation of appropriate diagnosis, treatment and ongoing management of hypertension. The use of automated blood pressure devices in community settings such as pharmacies provide opportunities for additional blood pressure measurement; however, it is important to ensure that these measurements are comparable to those taken in physicians' offices using the same devices. We conducted a randomized controlled trial to assess whether blood pressure readings assessed by use of an automated device differed according to the setting, specifically in community pharmacies and family physicians' offices. METHODS: We included adults aged 65 years and older who did not live in long-term care facilities or in hospital. The trial was administered by volunteer peer health educators, family physicians and pharmacists in 2 midsized communities in Ontario from April to September 2010. The 5 participating family physicians mailed invitations to their eligible patients. Those who gave informed consent were randomly allocated to 1 of 2 assessment sequences: group A had their blood pressure measured at their physician's office, then at a pharmacy, then again at their physician's office; those in group B had their blood pressure measured at a pharmacy, then at their physician's office, then again at a pharmacy. An automated blood pressure device (BpTRU) was used in both settings. We calculated the differences in mean systolic and diastolic blood pressure, and we compared the readings at both settings and by sequence of assessment. RESULTS: In total, 275 adults completed the trial (mean age 75.9 yr, 49.5% male, 46.9% with a self-reported diagnosis of hypertension). There were no statistically significant differences in systolic or diastolic blood pressure measurements associated with the sequence of assessment or the setting. There was a significant difference in the overall mean systolic blood pressure between the 2 assessment sequences (group A 122.0 v. group B 127.8 mm Hg, p < 0.001). INTERPRETATION: Automated devices used in pharmacies to measure blood pressure provide accurate and valid information that can be used in the diagnosis and management of hypertension among older adults in the community. TRIAL REGISTRATION: www.controlled-trials.com, no. ISRCTN91799042.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.007
metaresearch head score (Gemma)0.012
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.008
Threshold uncertainty score0.036

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0070.012
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0060.003
Bibliometrics0.0010.001
Science and technology studies0.0010.002
Scholarly communication0.0020.002
Open science0.0020.001
Research integrity0.0050.003
Insufficient payload (model declined to judge)0.0080.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.151
GPT teacher head0.396
Teacher spread0.246 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations40
Published2013
Admission routes4
Has abstractyes

Explore more

Same venueCMAJ OpenSame topicBlood Pressure and Hypertension StudiesFrench-language works237,207