Cost-effectiveness of cardiovascular magnetic resonance and single-photon emission computed tomography for diagnosis of coronary artery disease in Germany
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
BACKGROUND: Recent studies have demonstrated a superior diagnostic accuracy of cardiovascular magnetic resonance (CMR) for the detection of coronary artery disease (CAD). We aimed to determine the comparative cost-effectiveness of CMR versus single-photon emission computed tomography (SPECT). METHODS: Based on Bayes' theorem, a mathematical model was developed to compare the cost-effectiveness and utility of CMR with SPECT in patients with suspected CAD. Invasive coronary angiography served as the standard of reference. Effectiveness was defined as the accurate detection of CAD, and utility as the number of quality-adjusted life-years (QALYs) gained. Model input parameters were derived from the literature, and the cost analysis was conducted from a German health care payer's perspective. Extensive sensitivity analyses were performed. RESULTS: Reimbursement fees represented only a minor fraction of the total costs incurred by a diagnostic strategy. Increases in the prevalence of CAD were generally associated with improved cost-effectiveness and decreased costs per utility unit (ΔQALY). By comparison, CMR was consistently more cost-effective than SPECT, and showed lower costs per QALY gained. Given a CAD prevalence of 0.50, CMR was associated with total costs of €6,120 for one patient correctly diagnosed as having CAD and with €2,246 per ΔQALY gained versus €7,065 and €2,931 for SPECT, respectively. Above a threshold value of CAD prevalence of 0.60, proceeding directly to invasive angiography was the most cost-effective approach. CONCLUSIONS: In patients with low to intermediate CAD probabilities, CMR is more cost-effective than SPECT. Moreover, lower costs per utility unit indicate a superior clinical utility of CMR.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.002 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.002 | 0.003 |
| Bibliometrics | 0.000 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it