Validation of the Nova CRT8 for the measurement of ionized magnesium in feline serum

2005· article· en· W2126581045 on OpenAlexaff
Cornelia Gilroy, Shelley Burton, Barbara S. Horney, Allan MacKenzie

Bibliographic record

VenueVeterinary Clinical Pathology · 2005
Typearticle
Languageen
FieldNursing
TopicMagnesium in Health and Disease
Canadian institutionsUniversity of Prince Edward Island
Fundersnot available
KeywordsChromatographyChemistryDetection limitHemolysisCATSMagnesiumAnalyteBilirubinHemoglobinVenous bloodMedicineInternal medicineBiochemistry

Abstract

fetched live from OpenAlex

BACKGROUND: Evaluation of serum magnesium (Mg) concentration is becoming important in human and veterinary critical care medicine. An ion-selective electrode can measure the physiologically active ionized fraction. OBJECTIVES: The purpose of this study was to validate an ion-specific electrode analyzer and assay for measuring ionized Mg in feline serum and to determine a reference interval for this analyte in cats. METHODS: Venous blood samples were collected anaerobically from clinically healthy cats, and the serum was used to validate the analyzer and assay. This included investigating the stability of samples stored at different temperatures, intra- and interassay precision, linearity, analytical sensitivity, and potential interferences from bilirubin, lipemia, hemoglobin, or serum separator tubes. A reference interval was calculated. RESULTS: Serum samples evaluated for ionized Mg concentrations can be stored at 20 degrees C for < or =24 hours, at 4 degrees C for < or =72 hours, and at 20 degrees C for < or =4 weeks, when samples are minimally exposed to air. Intra- and interassay precisions had coefficients of variation (CVs) of 1.23% and 2.02%, respectively. There was good linearity using serum (r = .998; y = -0.0057 + 1.0256x) and manufacturer-supplied aqueous solutions and quality control materials (r = .999; y = 0.0110 + 0.9213x). Apparent analytical sensitivity was at least 0.015 mmol/L. Mean recovery was good for ionized Mg in samples with 1+ icterus (104%), 4+ lipemia (99.3%) and 1-4+ hemolysis (98.6%). There was no significant difference (P = .52) in ionized Mg concentrations in serum collected in tubes containing no additives compared with serum collected in glass separator tubes. The serum ionized Mg reference interval was 0.47-0.63 mmol/L (n = 40). CONCLUSIONS: The Nova CRT8 analyzer and assay provide a precise and reliable method of measuring ionized Mg concentration in feline serum. Strict adherence to sampling techniques, handling, and storage are necessary for reliable results.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.688
Threshold uncertainty score0.281

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.196
GPT teacher head0.426
Teacher spread0.231 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2005
Admission routes1
Has abstractyes

Explore more

Same venueVeterinary Clinical PathologySame topicMagnesium in Health and DiseaseFrench-language works237,207