MétaCan
Menu
Back to cohort

Fibrinogen estimates are influenced by methods of measurement and hemodilution with colloid plasma expanders

2010· article· en· W2127988410 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueTransfusion · 2010
Typearticle
Languageen
FieldMedicine
TopicTrauma, Hemostasis, Coagulopathy, Resuscitation
Canadian institutionsSt. Thomas Hospital
Fundersnot available
KeywordsFibrinogenFibrinCoagulationHydroxyethyl starchDilutionChemistryAlbuminChromatographyMedicineBiomedical engineeringInternal medicineImmunologyBiochemistry

Abstract

fetched live from OpenAlex

BACKGROUND: Measurement of plasma fibrinogen is often required in critically ill patients or massively bleeding patients being resuscitated with colloid plasma expander. This study aimed at evaluating different assays of plasma fibrinogen after in vitro dilution with commonly used plasma expanders and challenged the hypothesis that levels of fibrinogen are estimated significantly higher in plasma diluted with colloid plasma expander compared with isotonic saline. STUDY DESIGN AND METHODS: Fibrinogen measurements were established in plasma samples each diluted in vitro to 30 or 50% with isotonic saline, hydroxyethyl starch (HES) 130/0.4, and human albumin. Fibrinogen levels were assessed using an antigen determination, three photo-optical Clauss methods, one mechanical Clauss method, a prothrombin-derived method, and viscoelastic measurement through thromboelastometry. RESULTS: Measurement of fibrinogen levels was significantly different when performed on alternate analytical platforms. By 30 and 50% dilution with HES 130/0.4 coagulation analyzers using the photo-optical Clauss methods significantly overestimated levels of fibrinogen. Dilution with human albumin did not affect fibrinogen levels except from one analyzer by 50% dilution level. Viscoelastic measurement of fibrin polymerization was reduced at both dilution levels and appeared to reflect the impairment of fibrin polymerization induced by HES 130/0.4 and to a lesser extent human albumin. CONCLUSION: This study demonstrated that different automated coagulation analyzers revealed significantly different levels of fibrinogen. The presence of colloid plasma expander gave rise to erroneous high levels of fibrinogen returned from some coagulation analyzers employing the method of Clauss.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.151
Threshold uncertainty score0.532

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.298
Teacher spread0.276 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it