Gadolinium-Enhanced Magnetic Resonance Angiography for Pulmonary Embolism

2010· article· en· W2129444859 on OpenAlexaff
Paul D. Stein

Bibliographic record

VenueAnnals of Internal Medicine · 2010
Typearticle
Languageen
FieldMedicine
TopicVenous Thromboembolism Diagnosis and Management
Canadian institutionsUniversity of Calgary
FundersNational Heart, Lung, and Blood Institute
KeywordsMedicinePulmonary embolismMagnetic resonance imagingRadiologyMagnetic resonance angiographyPulmonary angiographyVenographyAngiographyThrombosisSurgery

Abstract

fetched live from OpenAlex

BACKGROUND: The accuracy of gadolinium-enhanced magnetic resonance pulmonary angiography and magnetic resonance venography for diagnosing pulmonary embolism has not been determined conclusively. OBJECTIVE: To investigate performance characteristics of magnetic resonance angiography, with or without magnetic resonance venography, for diagnosing pulmonary embolism. DESIGN: Prospective, multicenter study from 10 April 2006 to 30 September 2008. SETTING: 7 hospitals and their emergency services. PATIENTS: 371 adults with diagnosed or excluded pulmonary embolism. MEASUREMENTS: Sensitivity, specificity, and likelihood ratios were measured by comparing independently read magnetic resonance imaging with the reference standard for diagnosing pulmonary embolism. Reference standard diagnosis or exclusion was made by using various tests, including computed tomographic angiography and venography, ventilation-perfusion lung scan, venous ultrasonography, d-dimer assay, and clinical assessment. RESULTS: Magnetic resonance angiography, averaged across centers, was technically inadequate in 25% of patients (92 of 371). The proportion of technically inadequate images ranged from 11% to 52% at various centers. Including patients with technically inadequate images, magnetic resonance angiography identified 57% (59 of 104) with pulmonary embolism. Technically adequate magnetic resonance angiography had a sensitivity of 78% and a specificity of 99%. Technically adequate magnetic resonance angiography and venography had a sensitivity of 92% and a specificity of 96%, but 52% of patients (194 of 370) had technically inadequate results. LIMITATION: A high proportion of patients with suspected embolism was not eligible or declined to participate. CONCLUSION: Magnetic resonance pulmonary angiography should be considered only at centers that routinely perform it well and only for patients for whom standard tests are contraindicated. Magnetic resonance pulmonary angiography and magnetic resonance venography combined have a higher sensitivity than magnetic resonance pulmonary angiography alone in patients with technically adequate images, but it is more difficult to obtain technically adequate images with the 2 procedures.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.007
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.007
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.029
GPT teacher head0.331
Teacher spread0.302 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations386
Published2010
Admission routes1
Has abstractyes

Explore more

Same venueAnnals of Internal MedicineSame topicVenous Thromboembolism Diagnosis and ManagementFrench-language works237,207