MétaCan
Menu
Back to cohort
Record W2129682686 · doi:10.1002/cmr.b.21316

An <scp>RF</scp> breast coil for 0.2<scp>T</scp><scp>MRI</scp>

2015· article· en· W2129682686 on OpenAlexafffund
Barbara Błasiak, Vyacheslav Volotovskyy, Randy L. Tyson, Jonathan C. Sharp, Bogusław Tomanek

Bibliographic record

VenueConcepts in Magnetic Resonance Part B · 2015
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsUniversity of AlbertaUniversity of Calgary
FundersAlberta Innovates - Health Solutions
KeywordsElectromagnetic coilBreast MRIImage qualityMammographyBreast cancerRadiofrequency coilScannerRadio frequencyBreast imagingNoise (video)PopulationMedicineComputer scienceMagnetic resonance imagingBiomedical engineeringRadiologyArtificial intelligenceCancerTelecommunicationsEngineeringElectrical engineeringImage (mathematics)

Abstract

fetched live from OpenAlex

ABSTRACT Breast cancer is the most frequently diagnosed cancer in women. High field studies have shown the diagnostic value of breast MRI, but the examination costs greatly exceed those of competing conventional mammography. Low field MRI offers typical MRI contrast at substantially lower cost, but has suffered from lower spatial resolution. Specificity of breast MRI can potentially be increased by acquiring MR imaging with higher spatial or temporal resolution, but the signal‐to‐noise ratio (SNR) achievable in a given imaging time becomes limiting. SNR for the particular pulse sequence and magnet field strength is strongly influenced by the characteristics of the radio‐frequency coil. An optimal breast coil should yield excellent SNR but also generate a homogeneous B1 field, while allowing imaging of the both breasts simultaneously and maintaining patient comfort. RF receiver coil design is a key determinant of image quality, thus to address this we have designed and constructed a low field breast imaging coil. The coil was tested with a 4‐post 0.2T MRI providing high quality breast images. Designed and constructed saddle rf coil allows to obtain good quality image of the breast using low 0.2 T MRI system within 2 minutes. The coil provides patient comfort as breast compression is not required and minimizes artefacts caused by respiration or motion. A high contrast, low‐cost and pain‐free breast examination using optimized low field MRI system has the potential to serve a large patient population for whom current technologies have deficiencies. © 2015 Wiley Periodicals, Inc. Concepts Magn Reson Part B (Magn Reson Engineering) 46B: 3–7, 2016

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.012
Threshold uncertainty score0.042

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0120.006

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.031
GPT teacher head0.338
Teacher spread0.307 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2015
Admission routes2
Has abstractyes

Explore more

Same venueConcepts in Magnetic Resonance Part BSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207