MétaCan
Menu
Back to cohort
Record W2130415523

Effect of cannulation surgery and restraint stress on the plasma corticosterone concentration in the rat: application of an improved corticosterone HPLC assay.

2003· article· en· W2130415523 on OpenAlexaff
Spencer Ling, Fakhreddin Jamali

Bibliographic record

VenuePubMed · 2003
Typearticle
Languageen
FieldMedicine
TopicHormonal Regulation and Hypertension
Canadian institutionsUniversity of Alberta
Fundersnot available
KeywordsCorticosteroneHigh-performance liquid chromatographyChromatographyChemistryEthyl acetateJugular veinEndocrinologyInternal medicineMedicineHormoneBiochemistry
DOInot available

Abstract

fetched live from OpenAlex

PURPOSE: Stress increases plasma corticosterone concentration in rats. We studied the time-course of plasma corticosterone post jugular vein cannulation, a potential stress producing process, and after 1 h restraint stress using an improved assay. Current HPLC methods for corticosterone analysis require long extraction times with large volumes of solvent. METHODS: Adult male, Sprague-Dawley rats were used. Tail vein blood samples were collected from uncannulated rats (n=4). Other rats were cannulated in the right jugular vein, allowed to recover overnight and assigned to days 1, 2, 3 or 4 groups (n=4-6/group). Blood was sampled before and after exposure to 1 h of restraint stress. Plasma was separated and extracted with 5 mL ethyl acetate (betamethasone as internal standard), and then the extract was washed with sodium hydroxide (0.1 M) and water. After evaporation of ethyl acetate, the residue was dissolved in mobile phase (acetonitrile-water-acetic acid-TEA, 22:78:0.1:0.03, v/v) and injected into an isocratic HPLC consisting of a 10 cm C18 column, and UV detector at 254 nm. RESULTS: The minimum quantifiable concentration was 10 ng/mL of corticosterone based on 0.5 mL plasma. The standard curve was linear over the concentration range of 10-500 ng/mL. The extraction efficiency was 84-87%. The coefficient of variation for intra-day and inter-day precision was <10% with <8% error. Plasma corticosterone before cannulation (74 +/- 17 ng/mL) and those measured daily before restraint stress were not significantly different from one day to another (day 1, 60 +/- 21; day 2, 59 +/- 39, day 3, 45 +/- 23, and day 4, 41 +/- 8 ng/mL). Exposure to restraint stress elevated corticosterone (day 1, 122 +/- 33; day 2, 82 +/- 23; day 3, 148 +/- 33; and day 4, 134 +/- 20 ng/mL). Except on day 2, all concentrations were significantly elevated as compared to the pre-stress levels. CONCLUSIONS: Corticosterone concentrations were stable after jugular vein cannulation, and were increased by restraint stress. The present assay is a more convenient method as compared to those previously reported.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.786
Threshold uncertainty score0.215

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.242
Teacher spread0.222 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations44
Published2003
Admission routes1
Has abstractyes

Explore more

Same venuePubMedSame topicHormonal Regulation and HypertensionFrench-language works237,207