Measurements of thermal field at the stack extremities of a standing wave thermoacoustic heat pump
Bibliographic record
Abstract
In this paper, we experimentally measure the temperature fields at different locations on the stack plate and in the surrounding working fluid in a standing wave thermoacoustic device.The temperature measurements at the stack extremities and at the neighboring gas show axial heat transfer at the stack extremities, as opposed to the hypothesis of a perfectly isolated stack used in the linear thermoacoustic theory.Four different mechanisms of heat transfer are identified at the stack extremities in the present study.This information is necessary for the optimization of the performances of practical thermoacoustic engines.For the selected operating conditions, temperature measurements along the stack reveal a linear behavior along the stack and the corresponding gas residing near the stack.Temperature gradient along the working fluid is higher than that of along the stack, as opposed to the equal temperature gradient assumed by the linear theory.This information might be incorporated into the linear thermoacoustic theory to accurately predict the temperature difference generated across the stack ends.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.001 | 0.001 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.001 | 0.000 |
| Research integrity | 0.001 | 0.001 |
| Insufficient payload (model declined to judge) | 0.002 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".