MétaCan
Menu
Back to cohort
Record W2131683736 · doi:10.1155/2013/781690

Reduction of Central Line‐Associated Bloodstream Infection Rates in a Neonatal Intensive Care Unit after Implementation of a Multidisciplinary Evidence‐Based Quality Improvement Collaborative: A Four‐Year Surveillance

2013· article· en· W2131683736 on OpenAlexaffabout
Joseph Ting, Vicki SK Goh, Horacio Osiovich

Bibliographic record

VenueCanadian Journal of Infectious Diseases and Medical Microbiology · 2013
Typearticle
Languageen
FieldHealth Professions
TopicCentral Venous Catheters and Hemodialysis
Canadian institutionsUniversity of British Columbia
Fundersnot available
KeywordsMedicineNeonatal intensive care unitCatheterCentral lineCentral venous catheterEmergency medicineBloodstream infectionIntensive careIncidence (geometry)Quality managementIntensive care unitObservational studyInfection controlPediatricsIntensive care medicineSurgeryInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: The use of central venous catheters has permitted lifesaving treatment for critically ill neonates; however, the attributable mortality rate for central line-associated bloodstream infections (CLABSIs) has been estimated to be between 4% and 20%. In 2006/2007, the authors' neonatal intensive care unit (NICU) had a CLABSI rate that was nearly twofold higher than that reported by other Canadian NICUs. OBJECTIVE: To implement a quality improvement collaborative to reduce the incidence of neonatal CLABSI. METHODS: A retrospective observational study was performed to compare CLABSI in neonates admitted to the authors' level III NICU between August 2007 and March 2011. The entire study period was divided into four time periods to evaluate secular trends. A comprehensive catheter-related bloodstream infection prevention initiative was implemented in August 2007. The initiatives included staff education, standardization of skin preparation protocol, introduction of new antiseptic agents, implementation of central catheter insertion and maintenance checklists, reinforcement of the use of maximal sterile barrier precautions, and revision of the central catheter configuration and maintenance protocols. RESULTS: The median CLABSI rate of 7.9 per 1000 catheter days at the beginning of the study (period 1 [August 2007 to June 2008]) gradually decreased over the entire study period (P=0.034): period 2 (July 2008 to May 2009), 3.3 per 1000 catheter days; period 3 (June 2009 to April 2010), 2.6 per 1000 catheter days; and period 4 (May 2010 to March 2011), 2.2 per 1000 catheter days. CONCLUSION: A multidisciplinary evidence-based quality improvement collaborative resulted in a significant reduction in the CLABSI rate. Continuous quality improvement measures are required to reduce catheter-related bloodstream infections among low-birth-weight infants.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.128
Threshold uncertainty score0.925

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.025
GPT teacher head0.363
Teacher spread0.338 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations39
Published2013
Admission routes2
Has abstractyes

Explore more

Same venueCanadian Journal of Infectious Diseases and Medical MicrobiologySame topicCentral Venous Catheters and HemodialysisFrench-language works237,207