MétaCan
Menu
Back to cohort
Record W2132644776 · doi:10.1039/c1an15688h

Experimental investigation of beam heating in a soft X-ray scanning transmission X-ray microscope

2011· article· en· W2132644776 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueThe Analyst · 2011
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced X-ray Imaging Techniques
Canadian institutionsBrockhouse Institute for Materials ResearchMcMaster University
Fundersnot available
KeywordsMicroscopeBeam (structure)CrystalliteX-rayMaterials scienceOpticsOptical microscopeTransmission (telecommunications)Sample (material)Analytical Chemistry (journal)Scanning electron microscopeChemistryComposite materialPhysicsMetallurgy

Abstract

fetched live from OpenAlex

A variable temperature sample holder with an operational range of 15 to 200 °C and an accuracy of ±1 °C has been fabricated for scanning transmission X-ray microscopes (STXM). Here we describe the device, and use it to image the polycrystalline morphology of solid stearic acid and palmitic acid at temperatures near their respective melting points as a means of checking for possible sample heating caused by the focused X-ray beam. The melting points observed in STXM were identical to those observed by conventional methods within measurement uncertainty, even under the most extreme, high dose rate imaging conditions investigated. The beam-induced temperature rise in the sample is inferred to be below 1 °C for dose rates of up to 2.7 GGy/s.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.094
Threshold uncertainty score0.346

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.280
Teacher spread0.256 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it