MétaCan
Menu
Back to cohort
Record W2132930486 · doi:10.1186/2054-3581-1-15

Risk Factors Associated with Hemodialysis Central Venous Catheter Malfunction; A Retrospective Analysis of a Randomized Controlled Trial

2014· article· en· W2132930486 on OpenAlexafffundabout
David Ward, Louise Moist, Jennifer M. MacRae, Nairne Scott‐Douglas, Jianguo Zhang, Marcello Tonelli, Charmaine E. Lok, Steven Soroka

Bibliographic record

VenueCanadian Journal of Kidney Health and Disease · 2014
Typearticle
Languageen
FieldHealth Professions
TopicCentral Venous Catheters and Hemodialysis
Canadian institutionsDalhousie UniversityToronto General HospitalUniversity of TorontoUniversity Health NetworkLondon Health Sciences CentreWestern UniversityUniversity of AlbertaUniversity of Calgary
FundersUniversity of British Columbia
KeywordsMedicineHemodialysisRandomized controlled trialCatheterCentral venous catheterHeparinSurgeryInternal medicineAnesthesia

Abstract

fetched live from OpenAlex

BACKGROUND: We previously reported a reduction in central venous catheter (CVC) malfunction when using once-weekly recombinant tissue-plasminogen activator (rt-PA) as a locking solution, compared with thrice-weekly heparin. OBJECTIVES: To identify risk factors for CVC malfunction to inform a targeted strategy for rt-PA use. DESIGN: Retrospective analysis. SETTING: Canadian hemodialysis (HD) units. PATIENTS: Adults with newly placed tunnelled upper venous system CVCs randomized to a locking solution of rt-PA(1 mg/mL) mid-week and heparin (5000 u/ml) on the other HD sessions, or thrice-weekly heparin (5000 u/ml). MEASUREMENTS: CVC malfunction (the primary outcome) was defined as: peak blood flow less than 200 mL/min for thirty minutes during a HD session; mean blood flow less than 250 mL/min for two consecutive HD sessions; inability to initiate HD. METHODS: Cox regression was used to determine the association between patient demographics, HD session CVC-related variables and the outcome of CVC malfunction. RESULTS: Patient age (62.4 vs 65.4 yr), proportion female sex (35.6 vs 48.4%), and proportion with first catheter ever (60.7 vs 61.3%) were similar between patients with and without CVC malfunction. After multivariate analysis, risk factors for CVC malfunction were mean blood processed < 65 L when compared with ≥ 85 L in the prior 6 HD sessions (HR 4.36; 95% CI, 1.59 to 11.95), and mean blood flow < 300 mL/min, or 300 - 324 mL/min in the prior 6 HD sessions (HR 7.65; 95% CI, 2.78 to 21.01, and HR 5.52; 95% CI, 2.00 to 15.23, respectively) when compared to ≥ 350 mL/min. LIMITATIONS: This pre-specified post-hoc analysis used a definition of CVC malfunction that included blood flow, which may result in an overestimate of the effect size. Generalizability of results to HD units where trisodium citrate locking solution is used may also be limited. CONCLUSIONS: HD session characteristics including mean blood processed and mean blood flow were associated with CVC malfunction, while patient characteristics were not. Whether targeting these patients at greater risk of CVC malfunction with rt-PA as a locking solution improves CVC longevity remains to be determined.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.010
metaresearch head score (Gemma)0.020
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.010
Threshold uncertainty score0.054

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0100.020
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0030.004
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0020.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.280
Teacher spread0.264 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2014
Admission routes3
Has abstractyes

Explore more

Same venueCanadian Journal of Kidney Health and DiseaseSame topicCentral Venous Catheters and HemodialysisFrench-language works237,207